Novel optical system forin vitroquantification of full surface strain fields in small arteries: I. Theory and design
Authors:
- 22 February 2011
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 14 (3) , 213-225
Abstract
Recent advances in vascular biology and pathophysiology have revealed the need to understand better the genetic basis of arterial stiffness, disease progression and responses to clinical intervention. Towards this end, in vitro experiments on arteries from genetically modified mice promise to provide significantly increased insight into both health and disease. The need to test small arteries, often of complex shape, necessitates new methods for experimental arterial mechanics, however, ones that can provide information on local changes in geometry and strain. In this paper, we present a theoretical framework for a new panoramic digital image correlation-based method sufficient to collect such information and we demonstrate the utility of this approach via validation studies on phantoms having dimensions on the order of 500–1000 μm, similar to those of large mouse arteries. In particular, we show that placing the specimen within a conical mirror and imaging the specimen via a gimbal-mounted mirror using a single camera yields stereo information sufficient to quantify the size, shape and deformation along the full length and around the entire circumference of small arteries. In a companion paper, we show further that this approach can be implemented effectively while testing arteries within a physiological solution that maintains native biomechanical properties.Keywords
This publication has 13 references indexed in Scilit:
- Biomechanical and Microstructural Properties of Common Carotid Arteries from Fibulin-5 Null MiceAnnals of Biomedical Engineering, 2010
- Importance of pulsatility in hypertensive carotid artery growth and remodelingJournal Of Hypertension, 2009
- Mechanics of Carotid Arteries in a Mouse Model of Marfan SyndromeAnnals of Biomedical Engineering, 2009
- Quantification of the mechanical behavior of carotid arteries from wild-type, dystrophin-deficient, and sarcoglycan-δ knockout miceJournal of Biomechanics, 2008
- Strain field measurements on mouse carotid arteries using microscopic three‐dimensional digital image correlationJournal of Biomedical Materials Research Part A, 2007
- A Multiaxial Computer-Controlled Organ Culture and Biomechanical Device for Mouse Carotid ArteriesJournal of Biomechanical Engineering, 2004
- Multiaxial Mechanical Behavior of Human Saccular AneurysmsComputer Methods in Biomechanics and Biomedical Engineering, 2001
- ERROR ASSESSMENT FOR STRAIN MAPPING BY DIGITAL IMAGE CORRELATIONExperimental Techniques, 1998
- A triplane video-based experimental system for studying axisymmetrically inflated biomembranesIEEE Transactions on Biomedical Engineering, 1995
- High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approachJournal of Biomechanics, 1988