Abstract
Phenotyping of chronic obstructive pulmonary disease (COPD) with computed tomography (CT) is used to distinguish between emphysema- and airway-dominated type. The phenotype is reflected in correlations with lung function measures. Among these, the relative value of body plethysmography has not been quantified. We addressed this question using CT scans retrospectively collected from clinical routine in a large COPD cohort. Three hundred and thirty five patients with baseline data of the German COPD cohort COPD and Systemic Consequences-Comorbidities Network were included. CT scans were primarily evaluated using a qualitative binary emphysema score. The binary score was positive for emphysema in 52.5% of patients, and there were significant differences between the positive/negative groups regarding forced expiratory volume in 1 second (FEV1), FEV1/forced vital capacity (FVC), intrathoracic gas volume (ITGV), residual volume (RV), specific airway resistance (sRaw), transfer coefficient (KCO), transfer factor for carbon monoxide (TLCO), age, pack-years, and body mass index (BMI). Stepwise discriminant analyses revealed the combination of FEV1/FVC, RV, sRaw, and KCO to be significantly related to the binary emphysema score. The additional positive predictive value of body plethysmography, however, was only slightly higher than that of the conventional combination of spirometry and diffusing capacity, which if taken alone also achieved high predictive values, in contrast to body plethysmography. The additional information on the presence of CT-diagnosed emphysema as conferred by body plethysmography appeared to be minor compared to the well-known combination of spirometry and CO diffusing capacity.Keywords
Funding Information
- MSD Sharp & Dohme GmbH (BMBF with grant number 01 GI 0881)
This publication has 29 references indexed in Scilit:
- Pulmonary Emphysema in Cystic Fibrosis Detected by Densitometry on Chest Multidetector Computed TomographyPLOS ONE, 2013
- Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease: systematic review and meta-analysisEuropean Radiology, 2012
- Six-Minute Walk Distance Predictors, Including CT Scan Measures, in the COPDGene CohortChest, 2012
- Total lung capacity by plethysmography and high-resolution computed tomography in COPDInternational Journal of Chronic Obstructive Pulmonary Disease, 2012
- The relationship between lung function impairment and quantitative computed tomography in chronic obstructive pulmonary diseaseEuropean Radiology, 2011
- Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantificationEuropean Journal of Radiology, 2010
- Genetic Epidemiology of COPD (COPDGene) Study DesignCOPD: Journal of Chronic Obstructive Pulmonary Disease, 2010
- Monitoring the Progress of Emphysema by Repeat Computed Tomography Scans with Focus on Noise ReductionProceedings of the American Thoracic Society, 2008
- Diffusing capacity for nitric oxide: Reference values and dependence on alveolar volumeRespiratory Medicine, 2007
- Utility of lung density measurements in the diagnosis of emphysemaRespiratory Medicine, 2007