The transient behavior of Peltier junctions pulsed with supercooling
Authors:
- 1 July 2012
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (1) , 014514
Abstract
There exists the transient thermoelectric supercooling effect that can be enhanced by keeping on increasing the Peltier cooling effect to compensate for the Joule heating effect and Fourier heat conduction effect arriving at the cold junction, in which a transient cold spike can be produced by superimposing an additional shaped current pulse of a large magnitude on the original steady-state optimum value. Most previous work on the transient supercooling mainly focused on the minimum supercooling temperature achievable and separately analyzed the beneficial or detrimental effects on the transient supercooling performance, which was not clarified quantitatively to what extent the interactional effects were on the enhancement of the transient supercooling performance. In this work, we systematically investigate a numerical solution involving time-dependent imposed voltage pulse and time-dependent thermal boundary conditions on the transient supercooling behavior as well as the response of characteristic time and cold-junction temperature distribution to the pulse operation parameters during the periods of pulse start-up, pulse-on time, and pulse-off time, which is served as a theoretical basis for exploiting the coupling interaction of the thermoelectric effects on the heat diffusion from or to the cold junction interrelated with the amount of the availably electrical conversion in the short time scale. Additionally, the advantage of certain pulse forms over others is described. The results indicate that Peltier supercooling capacity shows a decreasing monotonic trend in proportion to the total amount of electrical conversion, and the maximum coefficient of performance for cooling state is about 0.5 to be achieved at steady state. Taking advantage of the temporary Peltier effect focused electrical conversion as the additional cooling for a period long enough against the earlier arrival of the excessively Joule heating dominated heat accumulation is the key parameter for the significant level of thermal enhancement on the pulse supercooling. The discussions may be attractive for compact thermal system coupled with pulsed Peltier supercooling to come up to the localized cooling level of high power packaging.Keywords
This publication has 18 references indexed in Scilit:
- Analysis of thermoelectric cooler performance for high power electronic packagesApplied Thermal Engineering, 2010
- Transient cooling of thermoelectric coolers and its applications for microdevicesEnergy Conversion and Management, 2005
- Supercooling of Peltier cooler using a current pulseJournal of Applied Physics, 2002
- Fast transient behavior of thermoelectric coolers with high current pulse and finite cold junctionEnergy Conversion, 1979
- Numerical analysis of transient behavior of thermoelectric coolersEnergy Conversion, 1977
- Some further remarks on the improvement of Peltier junctions for thermoelectric coolingEnergy Conversion, 1974
- New applications of thermoelements for cooling semiconductor devicesProceedings of the IEEE, 1968
- Experiments with Peltier Junctions Pulsed with High Transient CurrentsJournal of Applied Physics, 1963
- Study of the fast transient behaviour of peltier junctionsSolid-State Electronics, 1961
- The interpretation of the stationary and transient behaviour of refrigerating thermocouplesSolid-State Electronics, 1960