Image Retake Analysis in Digital Radiography Using DICOM Header Information
- 1 July 2008
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 22 (4) , 393-399
Abstract
A methodology to automatically detect potential retakes in digital imaging, using the Digital Imaging and Communications in Medicine (DICOM) header information, is presented. In our hospital, neither the computed radiography workstations nor the picture archiving and communication system itself are designed to support reject analysis. A system called QCOnline, initially developed to help in the management of images and patient doses in a digital radiology department, has been used to identify those images with the same patient identification number, same modality, description, projection, date, cassette orientation, and image comments. The pilot experience lead to 6.6% and 1.9% repetition rates for abdomen and chest images. A thorough analysis has shown that the real repetitions were 3.3% and 0.9% for abdomen and chest images being the main cause of the discrepancy being the wrong image identification. The presented methodology to automatically detect potential retakes in digital imaging using DICOM header information is feasible and allows to detect deficiencies in the department performance like wrong identifications, positioning errors, wrong radiographic technique, bad image processing, equipment malfunctions, artefacts, etc. In addition, retake images automatically collected can be used for continuous training of the staff.Keywords
This publication has 13 references indexed in Scilit:
- Digital Repeat Analysis; Setup and OperationJournal of Digital Imaging, 2006
- Patient dosimetry and image quality in digital radiology from online audit of the X-ray systemRadiation Protection Dosimetry, 2005
- The DIMOND project and its impact on radiation protectionRadiation Protection Dosimetry, 2005
- Guest Editorial, Preface, Main Points, Glossary and Chapter 1Annals of the ICRP, 2004
- Is Reject Analysis Necessary after Converting to Computed Radiography?Journal of Digital Imaging, 2002
- The challenge of governance: achieving quality in diagnostic imagingRadiography, 2001
- Comparative reject analysis in conventional film-screen and digital storage phosphor radiographyEuropean Radiology, 1999
- X-ray film reject analysis as a quality indicatorRadiography, 1998
- Quality control of storage phosphor digital radiography systemsJournal of Digital Imaging, 1995
- Reject analysis: a pilot programme for image quality managementEuropean Journal of Radiology, 1991