Bronchial artery perfusion during cardiopulmonary bypass does not prevent ischemia of the lung in piglets: assessment of bronchial artery blood flow with fluorescent microspheres
Authors:
- Christian SchlensakCSChristian Schlensak
- Torsten DoenstTDTorsten Doenst
- Stefan PreußerSPStefan Preußer
- Mark WunderlichMWMark Wunderlich
- Manuela KleinschmidtMKManuela Kleinschmidt
- Friedhelm BeyersdorfFBFriedhelm Beyersdorf
- 1 March 2001
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 19 (3) , 326-332
Abstract
Blood supply of the lungs during total cardiopulmonary bypass (CPB) is limited to flow through the bronchial arteries. This study was undertaken to assess the bronchial artery blood flow during CPB with fluorescent microspheres in a piglet model. We subjected ten piglets (mean weight 5.0+/-0.5 kg) to 120 min of normothermic, total CPB without aortic cross-clamping, followed by 60 min of post-bypass perfusion. Fluorescent microspheres were injected into the left atrium or the aortic cannula or distal to the cannula to assess bronchial artery blood flow before, during and after CPB. The reference samples were taken from the descending aorta. We compared the different sites of injection. Tissue samples of the lungs were taken before and 60 min after CPB. Before CPB, total bronchial artery perfusion was 43.6+/-14.1 ml/min (4.8+/-1.3% of cardiac output) as by injection distal to the aortic cannula. These values were not different when microspheres were injected into the left atrium or the aortic cannula. There was no difference in scatter or in the amount of microspheres in the reference samples among the three injections sites. During CPB, bronchial artery perfusion was significantly decreased (4.4+/-2.4 ml/min vs. 40.0+/-5.0 ml/min before CPB) and returned to baseline values 60 min after CPB. Light microscopy of the tissue samples revealed alveolar septal thickening and a decrease in alveolar surface area after 60 min of reperfusion which was associated with a decreased capacity to oxygenate blood. (1) Bronchial artery blood flow can quantitatively be assessed during CPB when microspheres are injected into the ascending aorta and the reference samples are taken from the descending aorta. (2) Despite adequate perfusion pressure bronchial artery blood flow is decreased substantially during CPB. (3) The decrease in blood flow and the ultrastructural changes present at the end of CPB suggest the presence of low-flow ischemia of the lung during total CPB.Keywords
This publication has 11 references indexed in Scilit:
- Glossary: Methods for the measurement of coronary blood flow and myocardial perfusionBasic Research in Cardiology, 1996
- Validation of fluorescent-labeled microspheres for measurement of regional organ perfusionJournal of Applied Physiology, 1993
- Temperature alters bronchial blood flow response to pulmonary arterial obstructionJournal of Applied Physiology, 1987
- Bronchopulmonary Anastomotic and Noncoronary Collateral Blood Flow in Humans during Cardiopulmonary BypassChest, 1985
- Acute increase in anastomotic bronchial blood flow after pulmonary arterial obstructionJournal of Applied Physiology, 1984
- Bronchovascular adjustments after pulmonary embolismJournal of Applied Physiology, 1980
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977
- Bronchopulmonary precapillary blood flow during cardiopulmonary bypassAmerican Heart Journal, 1968
- Estimation of Flow Through Bronchial-Pulmonary Vascular Anastomoses with Use of T-1824 DyeCirculation, 1961
- Early Stages in the Development of Collateral Circulation to the Lung in the RatCirculation Research, 1960