Abstract
This paper describes a problem of measuring a gas flow temperature using thermocouples for which the time it takes to reach an equilibrium temperature is shorter than the duration of the measurement process. Results for the numerical simulation of a gas flow in a sensor used to measure a stagnation temperature in short-duration wind tunnels are presented. The conjugate problem of a sensor in a supersonic flow is solved and the flow field inside the stagnation chamber is calculated. The temperature of the thermocouple placed on an end of a stagnation chamber is determined. The results of simulating the thermocouple readings depend on time and the oncoming flow parameters. The obtained readings of the stagnation temperature sensor are taken as virtual experiment data, which are processed using experimental aerodynamics methods. The stepwise process and two-thermocouple methods are used to recover the stagnation temperature. A difference in thermocouple readings is a normalized thermocouple instrument function. True temperature readings are recovered by deconvolution. The recovered readings are compared with the initial values of the stagnation temperature in the incoming flow to the sensor. The sources of measurement errors are determined, and the applicability of experimental methods for determining the stagnation temperature in short-duration wind tunnels (including those whose parameters decrease with time) is substantiated.