Parallel transmit 7 T MRI for adult epilepsy pre‐surgical evaluation
Open Access
Abstract
Objective: To implement parallel transmit (pTx) 7T magnetic resonance imaging (MRI) in the pre‐surgical evaluation of 3T‐negative patients with drug‐resistant focal epilepsy, and to compare quality to conventional single transmit (specifically, circularly polarized [CP]) 7T MRI. Methods: We implemented a comparative protocol comprising both pTx and CP 7T MRI in consecutive adult candidates for epilepsy surgery who had negative or equivocal 3T MRI imaging. Here we report the outcomes from the first 31 patients. We acquired pTx and CP T 1 , T 2 , fluid‐attenuated inversion recovery (FLAIR) and edge‐enhancing gradient echo (EDGE) images, all in the same three‐dimensional (3D) 0.8 mm isotropic space. Two‐dimensional (2D) high‐resolution T 2 and T 2 *‐weighted sequences were acquired only in CP mode due to current technological limitations. Two neuroradiologists, a neurologist, and a neurosurgeon made independent, blinded quality and preference ratings of pTx vs CP images. Quantitative methods were used to assess signal dropout. Results: 7T revealed previously‐unseen structural lesions in nine patients (29%), confirmed 3T‐equivocal lesions in four patients (13%), and disproved 3T‐equivocal lesions in four patients (13%). Lesions were better visualized on pTx than CP in 57% of cases, and never better visualized on CP. Clinical management was altered by 7T in 18 cases (58%). Nine cases were offered surgical resection and one laser interstitial thermal therapy (LITT). Three cases were removed from the surgical pathway because of bilateral or extensive lesions. Five cases were offered stereo‐electroencephalography (sEEG) with better targeting (in three because the 7T lesion was deemed equivocal by the multi‐disciplinary team (MDT), and in two because the lesion was extensive). Blinded comparison confirmed significantly better overall quality of pTx FLAIR images ( F (2, 184) = 13.7, p = 2.88 × 10 −6 ), whereas pTx MP2RAGE images were subjectively non‐inferior and had improved temporal lobe coverage with quantitatively less signal drop‐out. Significance: pTx‐7T is implementable in a clinical pathway, changed management in 58% of patients where 3T + FDG‐PET had not enabled resection, and is superior to single transmit 7T MRI.Keywords
Funding Information
- National Institute for Health and Care Research (NIHR203312)
- Medical Research Council (MR/M008983/1, MR/N013433/1, MR/X502844/1)
This publication has 22 references indexed in Scilit:
- A teenage girl with drug-resistant epilepsy and a hippocampal angiocentric neuroepithelial tumor (ANET) – illustrative case of 7T MRI in clinical practiceSeizure: European Journal of Epilepsy, 2024
- Incidence and prevalence of major epilepsy-associated brain lesionsEpilepsy & Behavior Reports, 2022
- Improved detection of focal cortical dysplasia using a novel 3D imaging sequence: Edge-Enhancing Gradient Echo (3D-EDGE) MRINeuroImage: Clinical, 2020
- Pros and cons of ultra-high-field MRI/MRS for human applicationProgress in Nuclear Magnetic Resonance Spectroscopy, 2018
- Imaging at ultrahigh magnetic fields: History, challenges, and solutionsNeuroImage, 2018
- Effects of magnetization transfer on T 1 contrast in human brain white matterNeuroImage, 2016
- Recent applications of UHF‐MRI in the study of human brain function and structure: a reviewNMR in Biomedicine, 2015
- Clinical applications at ultrahigh field (7 T). Where does it make the difference?NMR in Biomedicine, 2015
- Epilepsy surgery in children and adultsThe Lancet Neurology, 2014
- FreeSurferNeuroImage, 2012