Comprehensive evaluation of the internal and external quality control to redefine analytical quality goals
Authors:
- 15 June 2018
- journal article
- research article
- Published by Croatian Society for Medical Biochemistry and Laboratory Medicine in Biochemia Medica
- Vol. 28 (2) , 020710
Abstract
The aim of this work is to design a selection algorithm for total allowable error (TEa) source using a graphic tool that, by integrating internal (IQC) and external (EQC) quality control performances, enables the laboratory to evaluate which TEa source better fits the test analytical performance. Two analytical performance indicators (bias and Sigma metrics) were estimated for 23 biochemistry tests during 2016. Bias was estimated on the EQC, and Sigma metrics was calculated through the results obtained in the IQC. The Sigma metrics was charted as a function of the bias (TEa%). Following the proposed algorithm (considering the hierarchy in the Milan 2014 consensus), the TEa was evaluated depending on two areas. One area in the chart was defined as the objective area in which the used TEa is the appropriate one for the analytical performance of the test under evaluation. For any test located outside this area, a performance re-evaluation was required using another source of TEa. In 19 out of 23 evaluated tests, the resulting analytical performance allowed for the selection of biologic variability as TEa source. In the four remaining cases, TEa sources of lesser hierarchy were selected. The graphic tool designed together with the proposed algorithm enabled the laboratory to standardize the selection procedure of the most appropriate TEa for the test analytical performance.Keywords
This publication has 16 references indexed in Scilit:
- Assessing precision, bias and sigma-metrics of 53 measurands of the Alinity ci systemClinical Biochemistry, 2017
- Utilizing global data to estimate analytical performance on the Sigma scaleClinical Biochemistry, 2016
- ASVCPguidelines: allowable total error guidelines for biochemistryVeterinary Clinical Pathology, 2013
- The CCLM contribution to improvements in quality and patient safetyClinical Chemistry and Laboratory Medicine (CCLM), 2012
- Errors in a Stat Laboratory: Types and Frequencies 10 Years LaterClinical Chemistry, 2007
- Why is the laboratory an afterthought for managed care organizations?Clinical Chemistry, 1996
- Precision requirements for cost-effective operation of analytical processesClinical Chemistry, 1990
- A multi-rule Shewhart chart for quality control in clinical chemistry.Clinical Chemistry, 1981
- Power functions for statistical control rules.Clinical Chemistry, 1979
- Performance characteristics of rules for internal quality control: probabilities for false rejection and error detection.Clinical Chemistry, 1977