Three-dimensional computed tomography overlay for pulmonary vein antrum isolation: Follow-up and clinical outcomes
- 1 June 2012
- journal article
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 20 (7-8) , 302-306
Abstract
To facilitate the creation of circumferential lines in pulmonary vein (PV) antrum isolation, three-dimensional (3D) navigation systems are used widely. Alternatively, 3D reconstructions of the left atrium (LA) can be superimposed directly on fluoroscopy to guide ablation catheters and to mark ablation sites. In 71 atrial fibrillation patients circumferential PV ablation was performed. 3D reconstructions of the LA were derived from contrast cardiac-computed tomography and circumferential PV isolation was performed. In subsequent ablation procedures, veins were re-isolated, and defragmentation or linear lesions were performed if necessary. Adequate 3D reconstructions were formed and registered to fluoroscopy in all patients. All veins, except 2 in one single patient, could be isolated, resulting in freedom of AF in 45 patients (63 %). In 19 patients a second procedure was performed, in which 2.7 ± 1.1 PV per patient were re-isolated; in 3 patients a third procedure was performed. After follow-up of 15 ± 8 months, 51 (91 %) of patients with paroxysmal and 10 (67 %) with persistent AF were free of AF. The results of 3D overlay for circumferential PV isolation are good, although the reconduction rate and need for subsequent ablations remains high, and the outcomes of this technique appear to be equivalent to other mapping techniques.Keywords
This publication has 26 references indexed in Scilit:
- Three‐Dimensional CT Overlay in Comparison to CartoMerge for Pulmonary Vein Antrum IsolationJournal of Cardiovascular Electrophysiology, 2010
- Prospective randomized comparison between the conventional electroanatomical system and three-dimensional rotational angiography during catheter ablation for atrial fibrillationHeart Rhythm, 2010
- Effect of Electroanatomically Guided Versus Conventional Catheter Ablation of Typical Atrial Flutter on the Fluoroscopy Time and Resource Use: A Prospective Randomized Multicenter StudyJournal of Cardiovascular Electrophysiology, 2009
- The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized studyEuropean Heart Journal, 2008
- Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: Accuracy and clinical valueHeart Rhythm, 2008
- Electrical isolation of pulmonary veins in patients with atrial fibrillation: reduction of fluoroscopy exposure and procedure duration by the use of a non-fluoroscopic navigation system (NavX®)EP Europace, 2006
- Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2006
- Cardiac Three-Dimensional Magnetic Resonance Imaging and Fluoroscopy MergingCirculation, 2005
- Registration of Three-Dimensional Left Atrial Computed Tomographic Images With Projection Images Obtained Using FluoroscopyCirculation, 2005
- Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Clinical Outcome and Mechanisms of Subsequent ArrhythmiasJournal of Cardiovascular Electrophysiology, 2005