Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence
- 17 September 2010
- journal article
- review article
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 26 (7) , 686-698
Abstract
Purpose: This article summarises the evolution of microwave array applicators for heating large area chest wall disease as an adjuvant to external beam radiation, systemic chemotherapy, and potentially simultaneous brachytherapy. Methods: Current devices used for thermotherapy of chest wall recurrence are reviewed. The largest conformal array applicator to date is evaluated in four studies: (1) ability to conform to the torso is demonstrated with a CT scan of a torso phantom and MR scan of the conformal water bolus component on a mastectomy patient; (2) specific absorption rate (SAR) and temperature distributions are calculated with electromagnetic and thermal simulation software for a mastectomy patient; (3) SAR patterns are measured with a scanning SAR probe in liquid muscle phantom for a buried coplanar waveguide CMA; and (4) heating patterns and patient tolerance of CMA applicators are characterised in a clinical pilot study with 13 patients. Results: CT and MR scans demonstrate excellent conformity of CMA applicators to contoured anatomy. Simulations demonstrate effective control of heating over contoured anatomy. Measurements confirm effective coverage of large treatment areas with no gaps. In 42 hyperthermia treatments, CMA applicators provided well-tolerated effective heating of up to 500 cm2 regions, achieving target temperatures of Tmin = 41.4 ± 0.7°C, T90 = 42.1 ± 0.6°C, Tave = 42.8 ± 0.6°C, and Tmax = 44.3 ± 0.8°C as measured in an average of 90 points per treatment. Conclusion: The CMA applicator is an effective thermal therapy device for heating large-area superficial disease such as diffuse chest wall recurrence. It is able to cover over three times the treatment area of conventional hyperthermia devices while conforming to typical body contours.Keywords
This publication has 66 references indexed in Scilit:
- Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrencePhysics in Medicine & Biology, 2010
- Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermiaPhysics in Medicine & Biology, 2009
- Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicatorsInternational Journal of Hyperthermia, 2009
- Hyperthermia MRI temperature measurement: Evaluation of measurement stabilisation strategies for extremity and breast tumoursInternational Journal of Hyperthermia, 2009
- Feasibility of concurrent treatment with the scanning ultrasound reflector linear array system (SURLAS) and the helical tomotherapy systemInternational Journal of Hyperthermia, 2008
- Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatmentsInternational Journal of Hyperthermia, 2008
- Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermiaCancer, 2006
- Methods and potentials of magnetic resonance imaging for monitoring radiofrequency hyperthermia in a hybrid systemInternational Journal of Hyperthermia, 2005
- 915 MHz microwave interstitial hyperthermia. Part I: Theoretical and experimental aspects with temperature control by multifrequency radiometryInternational Journal of Hyperthermia, 1993
- Perturbations due to the use of catheters with non-perturbing thermometry probesInternational Journal of Hyperthermia, 1988