Stability, Survival, and Tolerability of a Novel Baha Implant System
Authors:
- Maarten J. F. de WolfMWMaarten J. F. de Wolf
- Myrthe K. S. HolMHMyrthe K. S. Hol
- Stina WigrenSWStina Wigren
- Mans Eeg-OlofssonMEMans Eeg-Olofsson
- Kevin GreenKGKevin Green
- Anneli KarlsmoAKAnneli Karlsmo
- Mark C. FlynnMFMark C. Flynn
- Joacim StalforsJSJoacim Stalfors
- Mike RotheraMRMike Rothera
- Emmanuel A. M. MylanusEMEmmanuel A. M. Mylanus
- Cor W. R. J. CremersCCCor W. R. J. Cremers
- 1 August 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 32 (6) , 1001-1007
Abstract
Determination of the difference in implant stability between a novel Baha implant system (test) and the previous-generation implant system (control). In an open, randomized, prospective multicenter clinical investigation, 77 adult patients with Baha implants were included. Test and control implants were randomly assigned in proportions of 2:1. Implant stability quotient (ISQ) values were recorded using resonance frequency analysis at the time of implantation and at 10 days, at 4, 6, 8, and 12 weeks, and at 6 months after surgery. Skin reactions were evaluated according to the Holgers classification. Sound processor fitting was performed from 6 weeks after implantation. Significantly higher mean ISQ values, measured between 0 and 6 months, were obtained for test compared to control implants (70.4 versus 65.4, p < 0.0001). Statistically significant differences were obtained for the study population as a whole and for the subgroup of patients loaded at 6 ± 1 weeks after implant surgery (63.6% of patients). Up to 12 weeks, Holgers rates were comparable, whereas at 6 months, more skin reactions (Grades 1 and 2) were observed in the control implant group. No reduction in mean ISQ values was observed after implant loading. The test implant showed higher mean ISQ values at the time of placement and over time. The level of osseointegration reached with the implants in adults as early as 6 weeks after implantation was sufficient to support the sound processor. The test implant system is expected to provide additional benefits related to the improvement of the degree of osseointegration, especially for patients with thin or compromised bone.Keywords
This publication has 35 references indexed in Scilit:
- An Experimental Evaluation of a New Craniofacial Implant Using the Rabbit Tibia ModelOtology & Neurotology, 2010
- An Experimental Evaluation of a New Craniofacial Implant Using the Rabbit Tibia ModelOtology & Neurotology, 2010
- Factors influencing resonance frequency analysis assessed by Osstell™mentor during implant tissue integration: II. Implant surface modifications and implant diameterClinical Oral Implants Research, 2010
- Clinical Outcome of the Simplified Surgical Technique for BAHA ImplantationOtology & Neurotology, 2008
- Osseointegration Timing for Baha System LoadingThe Laryngoscope, 2007
- Immediate Occlusal Loading of Brånemark System® TiUnite™ Implants Placed Predominantly in Soft Bone: 4‐Year Results of a Prospective Clinical StudyClinical Implant Dentistry and Related Research, 2005
- Osseointegration under Immediate Loading: Biomechanical Stress–Strain and Bone Formation–ResorptionImplant Dentistry, 2003
- Evaluation of implant losses and skin reactions around extraoral bone‐anchored implants: A 0‐ to 8‐year follow‐upOtolaryngology–Head and Neck Surgery, 2000
- Stability measurements of one-stage Brånemark implants during healing in mandiblesInternational Journal of Oral and Maxillofacial Surgery, 1999
- The Birmingham bone anchored hearing aid programme: surgical methods and complicationsThe Journal of Laryngology & Otology, 1996