Optimization of immunocytochemistry in cytology: comparison of two protocols for fixation and preservation on cytospin and smear preparations
Open Access
- 19 May 2014
- journal article
- research article
- Published by Wiley in Cytopathology
- Vol. 26 (1) , 38-43
Abstract
Objective A new protocol for fixation and slide preservation was evaluated in order to improve the quality of immunocytochemical reactions on cytology slides. Methods The quality of immunoreactions was evaluated retrospectively on 186 cytology slides (130 direct smears, 56 cytospins) prepared from different cytology samples. Ninety‐three of the slides were air dried, stored at −20 °C and fixed in acetone for 10 minutes (Protocol 1), whereas the other 93 were immediately fixed in methanol at −20 °C for at least 30 minutes, subsequently protected with polyethylene glycol (PEG) and stored at room temperature (Protocol 2). Immunocytochemical staining, with eight primary antibodies, was performed on a Ventana BenchMark Ultra instrument using an UltraView Universal DAB Detection Kit. The following parameters were evaluated for each immunoreaction: morphology preservation, intensity of specific staining, background and counterstain. The slides were blinded and independently scored by four observers with marks from 0 to 20. Results The quality of immunoreactions was better on methanol‐fixed slides protected with PEG than on air‐dried slides stored in the freezer: = 14.44 ± 3.58 versus = 11.02 ± 3.86, respectively (P < 0.001). Conclusion Immediate fixation of cytology slides in cold methanol with subsequent application of PEG is an easy and straightforward procedure that improves the quality of immunocytochemical reactions and allows the storage of the slides at room temperature.Keywords
This publication has 15 references indexed in Scilit:
- Immunocytochemistry: an indispensable technique in routine cytologyCytopathology, 2011
- Immunocytochemistry in Europe: results of the European Federation of Cytology Societies (EFCS) inquiryCytopathology, 2011
- External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) resultsCytopathology, 2011
- Documentation of immunocytochemistry controls in the cytopathologic literature: A meta‐analysis of 100 journal articlesDiagnostic Cytopathology, 2011
- Immunocytochemistry2008
- Assessing HER-2 status in fresh frozen and archival cytological samples obtained by fine needle aspiration cytologyCytopathology, 2004
- Immunostaining of cytology smears: A comparative study to identify the most suitable method of smear preparation and fixation with reference to commonly used immunomarkersDiagnostic Cytopathology, 2003
- Methods of Cytologic Smear Preparation and FixationActa Cytologica, 2000
- Use of alcohol fixed cytospins protected by 10% polyethylene glycol in immunocytology external quality assurance.Journal of Clinical Pathology, 1999
- Immunostaining of cell preparations: A comparative evaluation of common fixatives and protocolsDiagnostic Cytopathology, 1996