Microchamber Setup Characterization for Nanosecond Pulsed Electric Field Exposure
- 28 January 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (6) , 1656-1662
Abstract
Intracellular structures of biological cells can be disturbed by exposure to nanosecond pulsed electric field (nsPEF). A microchamber-based delivery system mounted on a microscope setup for real-time exposure to nsPEF is studied in this paper. A numerical and experimental characterization of the delivery system is performed both in frequency and time domains. The microchamber delivery system presents a high impedance compared to classical 50 Ω loads. Its frequency behavior and limits are investigated using an in-house finite-difference time-domain (FDTD) simulator and through experimental measurements. High-voltage measurements for two nsPEF generators are carried out. The applied pulse voltage measured across the microchamber electrodes is ~1 kV, corresponding to ~10 MV/m electric fields in the microchamber. Depending on the nsPEF generator used, the measured pulse durations are equal to 3.0 and 4.2 ns, respectively. The voltage distribution provided by FDTD simulations indicates a good level of homogeneity across the microchamber electrodes. Experimental results include permeabilization of biological cells exposed to 3.0-ns, 10-MV/m PEFs.Keywords
This publication has 36 references indexed in Scilit:
- Kilovolt, Nanosecond, and Picosecond Electric Pulse Shaping by Using Optoelectronic SwitchingIEEE Photonics Technology Letters, 2010
- A linear, single-stage, nanosecond pulse generator for delivering intense electric fields to biological loadsIEEE Transactions on Dielectrics and Electrical Insulation, 2009
- Scalable, compact, nanosecond pulse generator with a high repetition rate for biomedical applications requiring intense electric fields2009
- Plasma Membrane Voltage Changes during Nanosecond Pulsed Electric Field ExposureBiophysical Journal, 2006
- Fluorescence microscopy imaging of electroperturbation in mammalian cellsJournal of Biomedical Optics, 2006
- Dosimetric Analysis of a 900-MHz Rat Head Exposure SystemIEEE Transactions on Microwave Theory and Techniques, 2004
- Three-Dimensional Perfectly Matched Layer for the Absorption of Electromagnetic WavesJournal of Computational Physics, 1996
- A perfectly matched layer for the absorption of electromagnetic wavesJournal of Computational Physics, 1994
- FD-TD modeling of digital signal propagation in 3-D circuits with passive and active loadsIEEE Transactions on Microwave Theory and Techniques, 1994
- Modelling of dielectric losses in microstrip patch antennas: application of FDTD methodElectronics Letters, 1992