Comparison of Non-Invasive Methods for Measurement of Local Pulse Wave Velocity Using FSI-Simulations and In Vivo Data
- 13 November 2012
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (7) , 1567-1578
Abstract
In the search for better predictors of cardiovascular events, pulse wave velocity (PWV) has gained considerable interest. We compared three single-location methods to locally estimate PWV based on simultaneous measurements of pressure (P), velocity (U) or arterial diameter (D): the PU, ln(D)U and QA-method. First, the performance of these methods was analyzed using 3D fluid–structure interaction simulations (FSI) in a tube and patient-specific carotid artery. We demonstrated that the outcome was dependent on whether the methods were tested in the ideal conditions of a 3D axisymmetrical and reflection-free tube or in the more realistic setup of a carotid artery. The three single-location PWV methods performed similarly in the tube (4.29 m/s for PU, 4.44 m/s for ln(D)U and 4.38 m/s for QA) while the carotid data showed that the PU-method dramatically overestimates PWV (9.16 m/s), and the ln(D)U and QA-method underestimate (3.86 and 3.84 m/s, respectively). The erroneously high wavespeeds from the PU-method were attributed to wave reflections, which was confirmed by measurements in 37 healthy adults. This in vivo study showed similar discrepancies between the 3 single-location techniques as present in the carotid simulations, with the difference between the PU- and ln(D)U-method related to the magnitude of wave reflection.Keywords
This publication has 24 references indexed in Scilit:
- Numerical assessment of time-domain methods for the estimation of local arterial pulse wave speedJournal of Biomechanics, 2011
- Determination of wave speed and wave separation in the arteries using diameter and velocityJournal of Biomechanics, 2009
- The dicrotic notch as alternative time-reference point to measure local pulse wave velocity in the carotid artery by means of ultrasonographyJournal Of Hypertension, 2009
- Performance of a new partitioned procedure versus a monolithic procedure in fluid–structure interactionComputers & Structures, 2009
- Stability of a coupling technique for partitioned solvers in FSI applicationsComputers & Structures, 2008
- Confluence of incident and reflected waves interferes with systolic foot detection of the carotid artery distension waveformJournal Of Hypertension, 2008
- Is flow in the common carotid artery fully developed?Physiological Measurement, 2008
- Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breastJournal of Magnetic Resonance Imaging, 2002
- Determination of wave speed and wave separation in the arteriesJournal of Biomechanics, 2001
- Forward and Backward Running Waves in the Arteries: Analysis Using the Method of CharacteristicsJournal of Biomechanical Engineering, 1990