Early Detection Technique for Stator Winding Inter-Turn Fault in BLDC Motor Using Input Impedance
- 10 June 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 51 (1) , 240-247
Abstract
This paper proposes a diagnosis technique algorithm for a brushless dc motors under a stator inter-turn fault (ITF) condition using input impedance. The algorithm has early detection and various speed-range detection advantages. To early and accurately detect the ITF, the rotating speed, input current, voltage, resistance, and inductance must be analyzed. Therefore, we choose the input impedance as the detection factor because it includes all these factors. In this paper, the fault-detection system works without requiring a fast Fourier transform and the calculation of the negative-sequence impedance from the comparison of the measured impedance with the database impedance. The proposed technique was verified by the simulation and experiment.Keywords
Funding Information
- Energy Efficiency and Resources of the Korea Institute of Energy Technology Evaluation and Planning (KETEP)
- Korea government Ministry of Knowledge Economy (20122010100130)
This publication has 17 references indexed in Scilit:
- Minimization of Active Power and Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power Systems under Unbalanced Grid ConditionsJournal of Power Electronics, 2013
- Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault ConditionJournal of Power Electronics, 2013
- Comparison of the Fault Characteristics of IPM-Type and SPM-Type BLDC Motors Under Inter-Turn Fault Conditions Using Winding Function TheoryIEEE Transactions on Industry Applications, 2013
- Inductance Identification and Study of PM Motor With Winding Turn Short Circuit FaultIEEE Transactions on Magnetics, 2011
- Stator Interturn Fault Detection of Synchronous Machines Using Field Current and Rotor Search-Coil Voltage Signature AnalysisIEEE Transactions on Industry Applications, 2009
- An Improved Strategy to Detect Stator Inter-Turn Faults in Reluctance Synchronous Machines Using Both Negative Sequence Quantities and Stored Magnetic Energy After Supply Disconnection2007
- Comparison Between Finite-Element Analysis and Winding Function Theory for Inductances and Torque Calculation of a Synchronous Reluctance MachineIEEE Transactions on Magnetics, 2007
- Internal Short Circuit Fault Diagnosis for PM Machines Using FE-Based Phase Variable Model and Wavelets AnalysisIEEE Transactions on Magnetics, 2007
- An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives2007
- A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrixIEEE Transactions on Power Electronics, 2003