Silicone sampling tubes can cause drastic artifacts in measurements with aerosol instrumentation based on unipolar diffusion charging
Authors:
Open Access
- 13 October 2016
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 50 (12) , 1375-1384
Abstract
Aerosol instrumentation based on unipolar diffusion charging has become popular in the recent years. These instruments can be made very small, making them suitable as personal monitors. In many applications, including personal monitoring, the use of flexible sampling tubes is required. We found that degassing from these sampling tubes can alter the gas composition of the aerosol, which changes the ion properties in the unipolar charger. As a result, the particle concentrations, measured with a unipolar diffusion charger are biased. The strongest effect was found with new, conductive silicone tubes, because of the degassing of siloxanes. Results obtained with one miniature diffusion size classifier unit were by a factor of approximately two too low. Partector and Nanoparticle Surface Area Monitor showed in principle the same behavior, but to a lower degree. Other tube materials were found to have even the opposite effect, i.e., the measured concentrations increased, when measuring through a tube. The largest observed increase was, however, only approximately 14%. Tygon™ tubes were found to be the best compromise considering particle losses and effect on the diffusion charger. Copyright © 2016 American Association for Aerosol ResearchKeywords
This publication has 24 references indexed in Scilit:
- Sampling Artifacts from Conductive Silicone TubingAerosol Science and Technology, 2009
- Contamination from electrically conductive silicone tubing during aerosol chemical analysisAtmospheric Environment, 2009
- Chemical Vapor Deposition in the Corona Discharge of Electrostatic Air CleanersAerosol Science and Technology, 1998
- Morphology and Structure of Silicon Oxides Grown on Wire Electrodes by Positive DischargesJournal of the Electrochemical Society, 1989
- An approximation of the bipolar charge distribution for particles in the submicron size rangeJournal of Aerosol Science, 1988
- Unipolar Diffusion Charging of Ultrafine AerosolsAerosol Science and Technology, 1988
- Experimental Study of Particle Deposition in Bends of Circular Cross SectionAerosol Science and Technology, 1987
- ELECTROSTATIC EFFECTS IN AEROSOL SAMPLING AND FILTRATIONAnnals of Occupational Hygiene, 1985
- On the stationary charge distribution on aerosol particles in a bipolar ionic atmosphereGeofisica pura e applicata, 1963
- Gravity Settling of Particles in a Horizontal TubeJournal of the Air Pollution Control Association, 1958