Case series of mobile structures detected vividly by using superb microvascular imaging
Authors:
Open Access
- 14 October 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 6 (10) , ytac411
Abstract
Background: Superb microvascular imaging (SMI) is a new imaging technique that can reveal low-velocity blood flow without use of a contrast agent. SMI is based on an original algorithm and effectively removes tissue motion artifacts (clutter motion) from the background, thereby preserving visibility of low-velocity blood flow. SMI is expected to be useful for the evaluation of heart diseases, as well as blood vessels. Case summary: Here, we report three cases in which a mobile structure in the heart or a blood vessel was detected easily by strong enhancement on SMI. In the heart, the entire mass was strongly enhanced by colour-SMI and had the appearance of ‘a fire ball’. In the abdominal aorta and carotid artery, SMI captured a strongly enhanced echo image of a mass and revealed hyperechoic mobile plaque. It was hard to detect with the conventional echocardiography. Discussion: It is important to detect mobile intravascular and intracardiac structures as they are risk factors of thrombosis. Echo images are often strongly affected by the skill of the examiner, the patient's body habitus, and the presence of intestinal gas; thus, it is often difficult to detect a small mass with conventional echocardiography. With the use of SMI, even small mobile structures can be displayed at high intensity in comparison with the surrounding blood flow. Therefore, the non-invasive SMI was useful for the detection of mobile intravascular and intracardiac structures. Our findings of the current report may lead to new developments in SMI for imaging in the cardiac region.Keywords
Funding Information
- Canon Medical Systems Co. Ltd
This publication has 12 references indexed in Scilit:
- Clinical Applications of Superb Microvascular Imaging in the Liver, Breast, Thyroid, Skeletal Muscle, and Carotid PlaquesJournal of Ultrasound in Medicine, 2019
- Intraplaque Microvascular Flow Signal in Superb Microvascular Imaging and Magnetic Resonance Imaging Carotid Plaque Imaging in Patients with Atheromatous Carotid Artery StenosisJournal of Stroke and Cerebrovascular Diseases, 2018
- Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodulesBMC Medical Imaging, 2017
- Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of EmbolismJournal of the American Society of Echocardiography, 2016
- Morphological Classification of Mobile Plaques and Their Association with Early Recurrence of StrokeCerebrovascular Diseases, 2010
- Impact of Aortic Plaque Morphology on Survival Rate and Incidence of a Subsequent Embolic EventCirculation Journal, 2010
- A new clutter rejection algorithm for doppler ultrasoundIEEE Transactions on Medical Imaging, 2003
- Clutter filters adapted to tissue motion in ultrasound color flow imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2002
- Clinical and Echocardiographic Characteristics of Papillary FibroelastomasCirculation, 2001
- Value and limitations of the duke criteria for the diagnosis of infective endocarditisJACC, 1999