Effect of repetition rate of a pulsed microwave diamond forming plasma on the density of C2

Authors:

Abstract
The relative density of C2 in a pulsed microwave discharge, used for diamond deposition, was measured by optical emission spectroscopy. It was found that the average density of C2 increases with increasing plasma repetition rate (200 Hz–8 kHz) and approaches a limit at high frequencies. These results are explained with a simple plasma chemical kinetics simulation of the pulsed discharge.

This publication has 14 references indexed in Scilit: