Evaluation of 3D heads-up vitrectomy: outcomes of psychometric skills testing and surgeon satisfaction
Open Access
- 15 February 2018
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 32 (6) , 1093-1098
Abstract
Objectives To evaluate the use of a three-dimensional heads-up microscope (3DM) during 25-gauge pars plana vitrectomy (PPV) compared with a traditional ophthalmic microscope (TM) in terms of efficacy, safety, and teaching and learning satisfaction. Methods Prospective comparative interventional study. Fifty eyes affected by one of the following diseases: rhegmatogenous or tractional retinal detachment, epiretinal membrane, full-thickness macular hole, vitreous hemorrhage, or dropped lens. The 50 eyes were randomly assigned to one of two groups: group A (25 eyes) underwent 25-gauge PPV with 3DM, and group B (25 eyes) underwent 25-gauge PPV with TM. The main outcome measures were the duration of the operation, intraoperative complications, and surgeon and observer satisfaction. A questionnaire was used to assess surgeon satisfaction according to the following parameters: comfort, visibility, image quality, depth perception, simplicity of use, maneuverability, and teaching. A questionnaire to assess observer satisfaction was completed by 20 observers (surgical residents or ophthalmic surgeons). Results The degree of satisfaction was higher using 3DM for both surgeons and observers (P < 0.001). The average duration of the operation did not differ significantly between the two methods. No major complications occurred for either method. Conclusions PPV with 3DM is more comfortable for the surgeon and poses no substantially greater risk of complications for the patient. The high-definition screen delivers excellent depth perception and better screen parameter control, which results in high-quality surgical performance. 3DM surgery helps to significantly improve teaching and learning intra-operative surgical procedures.Keywords
This publication has 22 references indexed in Scilit:
- “HEADS UP” DIGITALLY ASSISTED SURGICAL VIEWING FOR RETINAL DETACHMENT REPAIR IN A PATIENT WITH SEVERE KYPHOSISRETINAL Cases & Brief Reports, 2018
- Vitrectomía 3 D. ¿Es realmente útil?Archivos de la Sociedad Española de Oftalmología, 2017
- Unassisted Scleral Depression During Vitrectomy Surgery: Two Simple, Cost-Effective TechniquesOphthalmic Surgery, Lasers and Imaging Retina, 2015
- The effects of absence of stereopsis on performance of a simulated surgical task in two-dimensional and three-dimensional viewing conditionsBritish Journal of Ophthalmology, 2014
- Ergonomics in thoracoscopic surgery: results of a survey among thoracic surgeonsInteractive CardioVascular and Thoracic Surgery, 2012
- Retinal light toxicityEye, 2010
- Phototoxicity to the Retina: Mechanisms of DamageInternational Journal of Toxicology, 2002
- PHOTOTOXIC RETINOPATHYOphthalmology Clinics of North America, 2001
- The Ferrier Lecture, 1992. Seeing depth with two eyes: stereopsisProceedings Of The Royal Society B-Biological Sciences, 1994
- Retinal damage by light in rats.1966