Crosswind Effects on Current Collection Quality of Railway Pantograph–Catenary: A Case Study in Chengdu–Chongqing Passenger Special Line
- 30 December 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
Abstract
As a common disturbance to the railway pantograph–catenary system, the crosswind usually deteriorates the current collection quality and threats to operational safety. The main topic of this article is to evaluate the effect of crosswind on the interaction performance of pantograph–catenary considering the aerodynamic forces acting on both the pantograph and catenary. The pantograph–catenary system of the Chengdu–Chongqing passenger special line is adopted as the analysis object. The absolute nodal coordinate formulation (ANCF) is employed to model the catenary. The numerical accuracy is validated via the comparison with the field measurement data collected from an inspection vehicle operating at 378 km/h. According to the quasi-steady theory, the wind load acting on the catenary is derived. Computational fluid dynamics (CFD) is employed to calculate the lift and drag forces acting on each component of the pantograph, which are used to derive the equivalent aerodynamic force that can be applied in the lumped-mass model. A special spatial grid is defined for the pantograph–catenary system to generate the fluctuating wind field based on the empirical spectrum. The simulation results indicate that the pantograph–catenary system of Chengdu–Chongqing passenger special railway has an acceptable performance with a crosswind speed of 20 m/s. However, when the crosswind increases up to 30 m/s, some contact force statistics exceed the safety threshold with a turbulence intensity of more than 17%. Through the analysis of the operational safety, it is found that the contact wire always works within the safety range of the pantograph head with a crosswind speed of 30 m/s. However, some safety issues can be seen from the maximum uplift of the pantograph head with a turbulence intensity of more than 21%.Keywords
Funding Information
- National Natural Science Foundation of China (U1734202, 52172408, 52102478)
This publication has 45 references indexed in Scilit:
- Introduction of variability into pantograph–catenary dynamic simulationsVehicle System Dynamics, 2014
- Estimation of Dynamic Contact Force Between a Pantograph and Catenary Using the Finite Element MethodJournal of Computational and Nonlinear Dynamics, 2012
- Comparison of Three-Dimensional Flexible Beam Elements for Dynamic Analysis: Classical Finite Element Formulation and Absolute Nodal Coordinate FormulationJournal of Computational and Nonlinear Dynamics, 2009
- Influence of the aerodynamic forces on the pantograph–catenary system for high-speed trainsVehicle System Dynamics, 2009
- An investigation into the mechanical damping characteristics of catenary contact wires and their effect on aerodynamic galloping instabilityProceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, 2003
- Fluctuating lift on a circular cylinder: review and new measurementsJournal of Fluids and Structures, 2003
- Probabilistic 3-D turbulence modeling for gust buffeting of structuresProbabilistic Engineering Mechanics, 2001
- Effect of Locomotive Vibrations on Pantograph-Catenary System DynamicsVehicle System Dynamics, 1998
- The suitability of the von Karman spectrum for the structure of turbulence in a complex terrain wind farmJournal of Wind Engineering and Industrial Aerodynamics, 1996
- THE SQUARE PRISM AS AN AEROELASTIC NON-LINEAR OSCILLATORQuarterly Journal of Mechanics and Applied Mathematics, 1964