Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography
- 1 September 2011
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (7) , 762-766
Abstract
Background CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible. Purpose To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). Material and Methods An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated): 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm). Results The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4–13.4 mSv and from 10.1–17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% ± 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% ± 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001). Conclusion Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner.Keywords
This publication has 22 references indexed in Scilit:
- Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiographyEuropean Journal of Radiology, 2010
- Triple-Rule-Out CT Angiography for Evaluation of Acute Chest Pain and Possible Acute Coronary SyndromeRadiology, 2009
- Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomographyEuropean Radiology, 2008
- Use of multislice CT for the evaluation of emergency room patients with chest pain: The so‐called “Triple rule‐out”Catheterization and Cardiovascular Interventions, 2007
- Dual-source computed tomography in patients with acute chest pain: feasibility and image qualityEuropean Radiology, 2007
- The Risk of Missed Diagnosis of Acute Myocardial Infarction Associated With Emergency Department VolumeAnnals of Emergency Medicine, 2006
- Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation programEuropean Radiology, 2006
- Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CTRadiology, 2003
- Missed Diagnoses of Acute Cardiac Ischemia in the Emergency DepartmentNew England Journal of Medicine, 2000
- Malpractice claims against emergency physicians in Massachusetts: 1975–1993The American Journal of Emergency Medicine, 1996