Abstract
Suction electrodes attached to tentacles of the sea anemone Calliactis parasitica record regular bursts of activity associated with the through‐conducting nerve net. Most bursts consist of 10–15 pulses at a frequency of 1 every 4 sec to 1 every 10 sec. The interval between bursts is usually 10–20 min. Regularity in pulse number and frequency in successive bursts suggests that the activity originates from a pacemaker. Bursts are always followed by slow contraction of endodermal longitudinal (parietal) muscles after a short delay, and endo‐dermal circular muscles after a long delay. A simple model for nervous pacemaker control of rhythmic contractions cannot be proposed as slow contractions can also occur in the absence of recorded nerve net activity.