Counting of residual WBCs in WBC-reduced blood components: a multicenter evaluation of a microvolume fluorimeter by the United Kingdom National Blood Service
- 1 January 2001
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 41 (1) , 93-101
Abstract
BACKGROUND: Implementation of universal WBC reduction of blood components means that automated analytical methods may be the only satisfactory way for production laboratories to meet increased testing requirements. STUDY DESIGN AND METHODS: A multicenter study on the performance of a microvolume fluorimeter (IMAGN 2000, Becton Dickinson) was undertaken on 519 RBC, 353 platelet, and 27 fresh plasma units. RESULTS: WBC counts for the RBC samples ranged from 0.02 to 6.94 × 106 per unit (mean, 0.57) as determined by FC and from 0.02 to 5.53 × 106 per unit (mean, 0.40) as determined by MVF with a mean FC bias of +0.15 × 106 WBCs per unit, and discrepancies outside the 95% limits of agreement were mainly associated with higher FC counts. The series of platelet samples showed means of 0.90 (range, 0.06‐19.45) and 0.66 (range, 0.01‐18.95) × 106 WBCs per unit for FC and MVF methods, respectively. FC and MVF results were in good agreement at low counts, although significant discrepancies were noted at higher counts. Overall, for the platelet units, there was a mean FC bias of +0.34 × 106 WBCs per unit. The intermethod agreement exceeded 99 percent for both types of blood component when the single (both UK and United States) decision point of 5.0 × 106 WBCs per unit was applied. The mean WBC counts for the 27 analyzed fresh plasma units were 61.8, 56.0, and 46.0 per μL by Nageotte hemocytometry, FC, and MVF, respectively. CONCLUSIONS: This evaluation found that the level of intersite consistency for FC was relatively poor compared to that for MVF. The results nevertheless validated the broad equivalence of FC and MVF results for the current Council of Europe and UK/US decision points of 6 WBCs per unit.Keywords
This publication has 16 references indexed in Scilit:
- Automatic volumetric capillary cytometry for counting white cells in white cell‐reduced plateletpheresis componentsTransfusion, 1997
- Enhanced flow cytometric method for counting very low numbers of white cells in platelet productsCytometry, 1996
- Volumetric capillary cytometry: A new method for absolute cell enumerationCytometry, 1996
- Practical guidelines for process validation and process control of white cell‐reduced blood components: report of the Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society of Blood Transfusion (ISBT)Transfusion, 1996
- Automation in quality assurance of blood components and the complementary role of auditTransfusion Science, 1995
- Validation of use of the Nageotte hemocytometer to count low levels of white cells in white cell-reduced platelet componentsTransfusion, 1994
- Large‐volume hemocytometer chamber for accurate counting of white cells (WBCs) in WBC‐reduced platelets: validation and application for quality control of WBC‐reduced platelets prepared by apheresis and filtrationTransfusion, 1993
- A flow cytometric method for counting very low levels of white cells in blood and blood componentsTransfusion, 1993
- Validation of a simple method to count very low white cell concentrations in filtered red cells or plateletsTransfusion, 1992
- A multicenter study on the efficiency of white cell reduction by filtration of red cellsTransfusion, 1991