Apparent Diffusion Coefficient of the Placenta and Fetal Organs in Intrauterine Growth Restriction
Authors:
- Ahmed Abdel Khalek Abdel RazekARAhmed Abdel Khalek Abdel Razek
- Mahmoud ThabetMTMahmoud Thabet
- Eman Abdel SalamESEman Abdel Salam
- 1 May 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 43 (3) , 507-512
Abstract
Purpose: This study aimed to assess apparent diffusion coefficient (ADC) of the placenta and fetal organs in intrauterine growth restriction (IUGR). Materials and methods: A prospective study of 30 consecutive pregnant women (aged 21–38 years with mean age of 31.5 years and a mean gestational week of 35 ± 2.3) with IUGR and 15 age-matched pregnant women was conducted. All patients and controls underwent diffusion-weighted magnetic resonance imaging. The ADCs of the placenta and fetal brain, kidney, and lung were calculated and correlated with neonates needing intensive care unit (ICU) admission. Results: There was a significant difference in ADC of the placenta and fetal brain, lung, and kidney (P = 0.001, 0.001, 0.04, and 0.04, respectively) between the patients and the controls. The cutoff ADCs of the placenta and fetal brain, lung, and kidney used to detect IUGR were 1.45, 1.15, 1.80, and 1.40 × 10−3 mm2/s, respectively, with areas under the curve (AUCs) of 0.865, 0.858, 0.812, and 0.650, respectively, and accuracy values of 75%, 72.5%, 72.5%, and 70%, respectively. Combined ADC of the placenta and fetal organs used to detect IUGR revealed an AUC of 1.00 and an accuracy of 100%. There was a significant difference in ADC of the placenta and fetal brain, lung, and kidney between neonates needing admission and those not needing ICU admission (P = 0.001, 0.001, 0.002, and 0.002, respectively). The cutoff ADCs of the placenta and fetal brain, lung, and kidney used to define neonates needing ICU were 1.35, 1.25, 1.95, and 1.15 × 10−3 mm2/s with AUCs of 0.955, 0.880, 0.884, and 0.793, respectively, and accuracy values of 86.7%, 46.7%, 76.7%, and 70%, respectively. Combined placental and fetal brain ADC used to define neonates needing ICU revealed an AUC of 0.968 and an accuracy of 93.3%. Conclusion: Combined ADC of the placenta and fetal organs can detect IUGR, and combined ADC of the placenta and fetal brain can define fetuses needing ICU.Keywords
This publication has 45 references indexed in Scilit:
- ACR Appropriateness Criteria® Growth Disturbances — Risk of Intrauterine Growth RestrictionUltrasound Quarterly, 2013
- Apparent diffusion coefficient values of mediastinal masses in childrenEuropean Journal of Radiology, 2012
- Diffusion magnetic resonance imaging of chest tumorsCancer Imaging, 2012
- Characterization of mediastinal lymphadenopathy with diffusion-weighted imagingMagnetic Resonance Imaging, 2011
- Role of diffusion-weighted MR imaging in assessing malignant versus benign skull-base lesionsLa radiologia medica, 2010
- Diffusion Weighted MR Imaging of the BreastAcademic Radiology, 2010
- Diffusion‐weighted MR imaging and apparent diffusion coefficient of the normal fetal lung: preliminary experiencePrenatal Diagnosis, 2008
- Use of uterine artery Doppler ultrasonography to predict pre-eclampsia and intrauterine growth restriction: a systematic review and bivariable meta-analysisCanadian Medical Association Journal, 2008
- MRI with diffusion‐weighted imaging (DWI) and apparent diffusion coefficient (ADC) assessment in the evaluation of normal and abnormal fetal kidneys: preliminary experiencePrenatal Diagnosis, 2007
- Pregnancy-Associated Plasma Protein A and Alpha-fetoprotein and Prediction of Adverse Perinatal OutcomeObstetrics & Gynecology, 2006