Testing sealed-tube Graphitization at the NERC Radiocarbon facility, east Kilbride
- 9 September 2019
- journal article
- conference paper
- Published by Cambridge University Press (CUP) in Radiocarbon
- Vol. 61 (6) , 1813-1822
Abstract
Graphitization of 0.5–1.5 mg C, and of smaller samples to a lesser extent, is routinely done at our Facility by reduction over zinc. The method yields low background, good accuracy but offers a limited throughput, requires dedicated equipment and considerable operator time. Sealed-tube graphitization is faster, easier and cost-efficient producing as many graphites as CO2 can be purified in one day with low background, good accuracy and precision, provided precise measurements of δ13C values can be attained by accelerator mass spectrometry (AMS) to correct for isotope fractionation (Xu et al. 2007). We tested sealed-tube graphitization on 0.1 to 1.0 mg C samples and found that while we were able to obtain low backgrounds of >57,000 ±1000 yr BP for ∼1.7 mg C and 41,230 ± 430 yr BP for ∼0.09 mg C (0.0008 ± 0.0001 and 0.0059 ± 0.0003 Fraction Modern, respectively), results were variable for sample sizes <0.5 mg C. Measurements of FIRI Belfast Cellulose and TIRI Barleymash showed 0.3–0.6% precision and 1% accuracy for most sample sizes. We found better results in our laboratory by introducing the following modifications: (1) shorter inner tube (2 cm long), (2) short flame-seal length (∼7–8 cm) and (3) keeping the inner tube with iron separate from the outer tube containing zinc and titanium hydride during cleaning.Keywords
This publication has 11 references indexed in Scilit:
- Optimization of the Amount of Zinc in the Graphitization Reaction for Radiocarbon AMS Measurements at LAC-UFFRadiocarbon, 2016
- Ultra Small-Mass Graphitization by Sealed Tube Zinc Reduction Method for AMS 14C MeasurementsRadiocarbon, 2013
- Optimization of Sealed Tube Graphitization Method for Environmental C-14 Studies Using MICADASNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2013
- Small-mass graphite preparation by sealed tube zinc reduction method for AMS 14C measurementsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2010
- Ultra small-mass AMS 14C sample preparation and analyses at KCCAMS/UCI FacilityNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2007
- Modifying a sealed tube zinc reduction method for preparation of AMS graphite targets: Reducing background and attaining high precisionNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2007
- Is there a Fifth International Radiocarbon Intercomparison (VIRI)?Radiocarbon, 2003
- Rapid Production of Graphite Without Contamination for Biomedical AMSRadiocarbon, 1992
- Preparation of Small Samples for 14C Accelerator Targets by Catalytic Reduction of CORadiocarbon, 1987
- Discussion Reporting of 14C DataRadiocarbon, 1977