Detection of coagulating blood under steady flow by statistical analysis of backscattered signals
Authors:
- Chih-Chung HuangChih-Chung Huang
- Po-Hsiang TsuiPTPo-Hsiang Tsui
- Shyh-Hau WangSWShyh-Hau Wang
- 26 February 2007
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 54 (2) , 435-442
Abstract
The main purpose of this study is to detect blood coagulation under flow condition by analyzing Nakagami statistical model of backscattered signals. The radiofrequency (RF) signals backscattered from flowing blood were measured with a 10-MHz focused transducer. A 30-ml aliquot of blood was circulated in the flow model, and 3 ml of 0.5 M calcium chloride solution was added to induce blood coagulation. The progression in the blood coagulation due to the addition of the calcium chloride solution resulted in the integrated backscatter being increased by 4.2 plusmn 0.5 dB, then tended to stabilize as the clot was formed. The Nakagami parameter was approximately 0.75 plusmn 0.1 for flowing blood during the initial stage of blood coagulation, and it increased rapidly to its highest level of 2.6 plusmn 0.5 during clotting. These experimental results demonstrate the feasibility of using the ultrasonic statistical parameter for detecting blood coagulation from flowing blood and provide a novel method for further monitoring the progress of clotting and thrombosis in vivoKeywords
This publication has 7 references indexed in Scilit:
- In Vitro Study on Assessment of Blood Coagulation and Clot Formation Using Doppler UltrasoundJapanese Journal of Applied Physics, 2005
- Detection of blood coagulation and clot formation using quantitative ultrasonic parametersUltrasound in Medicine & Biology, 2005
- The effect of logarithmic compression on estimation of the Nakagami parameter for ultrasonic tissue characterization: a simulation studyPhysics in Medicine & Biology, 2005
- The effect of transducer characteristics on the estimation of Nakagami paramater as a function of scatterer concentrationUltrasound in Medicine & Biology, 2004
- Non-Gaussian statistics and temporal variations of the ultrasound signal backscattered by blood at frequencies between 10 and 58 MHzThe Journal of the Acoustical Society of America, 2004
- Classification of ultrasonic B-mode images of breast masses using Nakagami distributionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2001
- A general statistical model for ultrasonic backscattering from tissuesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2000