Endotracheal intubation with airtraq® versus storz® videolaryngoscope in children younger than two years - a randomized pilot-study
Open Access
- 30 April 2012
- journal article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 12 (1) , 7
Abstract
Background: New laryngoscopes have become available for use in small children. The aim of the study was to compare the Storz® videolaryngoscope (SVL) to the Airtraq® Optical laryngoscope (AOL) for tracheal intubation in children younger than two years of age who had a normal airway assessment. Our hypothesis was that the SVL would have a better success rate than the AOL. Methods: Ten children aged 2 years or younger scheduled for elective cleft lip/palate surgery were included. The anesthesia was standardized and a Cormack-Lehane (CL)-score was obtained using a Macintosh laryngoscope. After randomization CL-score and endotracheal tube positioning in front of the glottis was performed with one device, followed by the same procedure and intubation with the other device. The video-feed was recorded along with real-time audio. The primary endpoint was the success rate, defined as intubation in first attempt. Secondary endpoints were the time from start of laryngoscopy to CL-score, tube positioning in front of the glottis, and intubation. Results: Two intubation attempts were needed in two of five patients randomized to the SVL. The difference in time (SVL vs. AOL) to CL-score was 4.5 sec (p = 0.0449). The difference in time (SVL vs. AOL) to tube positioning was 11.6 sec (p = 0.0015). Time to intubation was 29.0 sec for SVL and 15.8 sec for AOL. Conclusion: No difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq® Optical videolaryngoscope showed a number of time related advantages over the Storz® videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations. Trial registration: ClinicalTrials.gov; Identifier NCT01090726.Keywords
This publication has 14 references indexed in Scilit:
- Endotracheal intubation with Airtraq® optical laryngoscope in the pediatric patientsPediatric Anesthesia, 2011
- The difficult pediatric airway – a review of new devices for indirect laryngoscopy in children younger than two years of agePediatric Anesthesia, 2010
- Evaluation of airway equipment: man or manikin?Anaesthesia, 2010
- A comparison of the Glidescope ® and Karl Storz DCI ® videolaryngoscopes in a paediatric manikin*Anaesthesia, 2010
- The Airtraq may not be the solution for infants with difficult airwaysPediatric Anesthesia, 2010
- Airtraq optical laryngoscope: initial clinical experience in 20 childrenJournal of Anesthesia, 2009
- A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway – a randomized clinical trialPediatric Anesthesia, 2009
- More maneuvers to facilitate endotracheal intubation using the Airtraq® laryngoscope in children with difficult airwaysPediatric Anesthesia, 2009
- Pediatric laryngoscopes and intubation aids old and newPediatric Anesthesia, 2009
- Review of video laryngoscopy and rigid fiberoptic laryngoscopyCurrent Opinion in Anaesthesiology, 2008