Evaluation of an electronic portal imaging device (target view, ge) as a quality assurance tool
Authors:
- Piotr MileckiPMPiotr Milecki
- Sergiusz NawrockiSNSergiusz Nawrocki
- Julian MalickiJulian Malicki
- Grażyna StryczyńskaGSGrażyna Stryczyńska
- 1 January 2001
- journal article
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 6 (4) , 169-172
Abstract
SummaryPurposeA proper control of the geometrical accuracy of treated portals during radiotherapy results in higher quality of treatment and may lead to the increase in the therapeutic gain.In this work, an evaluation of an electronic portal imaging device (EPID) was made in the following aspects: the quality of images, the estimation of prolongation of the treatment, and the corrections introduced after EPIDs.Material and methodsWe have archived 2430 portal images of 184 patients who were irradiated at our department. The following significant errors were established: a shift in the field along x, y, z axes (more than 5 mm in the head and neck region, more than 7 mm in the chest tumours and 10 mm in pelvic region), a displacement of shield by the same values, and an erroneous field size assigment by more than 10 mm.ResultsThe introduction of the EPID into clinical practice involved approximately 10% of the session time. The quality of the electronic portal images received was acceptable for further analysis in 87% of the analysed group of patients. Significant errors have been registered in 33% of monitored patients. Prior to the treatment and during the set-up procedure, corrections were made in 20% of the evaluated patients.ConclusionsAn electronic portal imaging device (EPID) is a useful tool for fast and reliable portal image acquisitionKeywords
This publication has 7 references indexed in Scilit:
- Immobilizing and positioning patients for radiotherapySeminars in Radiation Oncology, 1995
- Interactive use of on-line portal imaging in pelvic radiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993
- Time trend of patient setup deviations during pelvic irradiation using electronic portal imagingRadiotherapy and Oncology, 1993
- Detection of systematic patient setup errors by portal film analysisRadiotherapy and Oncology, 1992
- Accuracy of radiation field alignment in clinical practiceInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1985
- Weekly localization films and detection of field placement errorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1978
- The Steepness of the Dose—Response Curve in Radiation TherapyRadiology, 1975