Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
Authors:
- James M. MassulloJMJames M. Massullo
- Tejinder P. SinghTSTejinder P. Singh
- Ward J. DunnicanWDWard J. Dunnican
- Brian R. BinettiBBBrian R. Binetti
Open Access
- 1 January 2012
- journal article
- Published by The Society of Laparoscopic and Robotic Surgeons in JSLS : Journal of the Society of Laparoscopic & Robotic Surgeons
- Vol. 16 (1) , 55-59
Abstract
Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted.Keywords
This publication has 28 references indexed in Scilit:
- Severe complication of laparoscopic mesh hiatoplasty for paraesophageal herniaSurgical Endoscopy, 2009
- Erosion of a Composite PTFE/ePTFE Mesh After Hiatal Hernia RepairSurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2009
- Laparoscopic Repair of Giant Paraesophageal Hernia Results in Long-Term Patient Satisfaction and a Durable RepairJournal of Gastrointestinal Surgery, 2008
- Metaanalysis of Recurrence After Laparoscopic Repair of Paraesophageal Hernia2008
- Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplicationsSurgical Endoscopy, 2006
- Open Repair of Paraesophageal Hernia: Reassessment of Subjective and Objective OutcomesThe Annals of Thoracic Surgery, 2005
- The History of Hiatal Hernia SurgeryAnnals of Surgery, 2005
- Laparoscopic mesh cruroplasty for large paraesophageal herniasSurgical Endoscopy, 2003
- Laparoscopic treatment of large paraesophageal herniasSurgical Endoscopy, 2000
- Laparoscopic repair of large type III hiatal hernia: objective followup reveals high recurrence rate1Journal of the American College of Surgeons, 2000