Abstract
SRAM memories are widely used as particle detectors in high radiation environments, as in the CERN accelerator complex. Multiple Cell Upsets (MCUs) characterized by a large number of SEUs may affect the measurement of particle fluxes, resulting in corrupted data and accuracy losses. A study of SEU bursts generation was carried out on an 8 Mbit 90-nm memory and a solution approach using a detection and correction algorithm implemented on an FPGA was investigated.Keywords