Aortic pseudoaneurysm repair after Bentall procedure using the IntraClude device
Authors:
Open Access
- 1 October 2020
- journal article
- case report
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (12) , 3617-3619
Abstract
Background Despite advances in surgical techniques, aortic reoperation is still associated with a high risk of mortality due to possible injury of the myocardium or great vessels during resternotomy. Materials & Methods We report the case of a giant aortic pseudoaneurysm, 17 years after the Bentall procedure in a 76‐year‐old male patient. Results Successful pseudoaneurysm resection after the Bentall procedure using the ThruPort IntraClude intra‐aortic occlusion device (Edwards Lifesciences) was achieved. Discussion The IntraClude catheter can be used effectively to provide endovascular clamping of the ascending aorta during challenging cardiac reoperations.Keywords
This publication has 7 references indexed in Scilit:
- Recent Developments in Minimally Invasive Cardiac Surgery: Evolution or Revolution?BioMed Research International, 2015
- Endoaortic Occlusion with the Intraclude Device during the Management of Ascending Aortic PseudoaneurysmInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2015
- Pulsatile Pseudoaneurysm Following a Bentall ProcedureJournal of Cardiac Surgery, 2011
- Reoperation for Giant False Aneurysm of the Thoracic Aorta: How to Reenter the Chest?The Annals of Thoracic Surgery, 2007
- Thrombosis of the Left Anterior Descending Artery Due to Compression from Giant Pseudoaneurysm Late After a Bentall OperationJournal of Cardiac Surgery, 2006
- Mediastinal false aneurysm after thoracic aortic surgeryThe Annals of Thoracic Surgery, 2000
- Reoperations on the ascending aorta and aortic root: pitfalls and results in 134 patientsThe Annals of Thoracic Surgery, 1999