Two-step calibration of a stereo camera system for measurements in large volumes

Authors:
  • MMM Machacek
    M Machacek

Abstract
Three-dimensional measurements with a stereo camera system are an established standard practice and are used in a wide range of different applications. However, the calibration of the camera parameters, a crucial step in the procedure carried out in order to find the relation between the real world and the digital image coordinates, is still associated with several difficulties. These include the accuracy, the implementation of the algorithms and the calibration procedure. A new method is presented taking into account in particular large measurement volumes where it is difficult to find a suitable calibration target and cases where frequent recalibrations are necessary because of camera position changes. The method is based on a two-step self-calibration with two different calibration targets, a planar target and a two-point target. It is shown that this approach creates an easy-to-implement algorithm and at the same time a simple calibration procedure. A thorough assessment o ft he accuracy of the two-step calibration method is presented.