Comparison of the efficacy and safety between a low-fluence 1064-nm Q-switched neodymium-doped yttrium aluminum garnet laser and a conventional Q-switched 532-nm laser for the treatment of cafe-au-lait macules in 40 Chinese children: a prospective, randomized, parallel-controlled, evaluator-blinded trial
Authors:
- 13 January 2021
- journal article
- research article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 37 (1) , 279-286
Abstract
Cafe-au-lait macules (CALMs) affect the appearance of patients and can result in serious psychological problems. Successful treatments without adverse effects remain challenging. We designed a prospective, randomized, controlled, evaluator-blinded trial on 40 pediatric patients to compare the efficacy between a low-fluence 1064-nm Q-switched Nd:YAG laser and a Q-switched Nd:YAG 532-nm laser for the treatment of solitary CALMs in children. We randomly assigned participants into 2 groups. We treated those in the first group with 3 sessions of 532-nm QS laser at 1-month intervals, and those in the second group with 6 sessions of 1064-nm LFQS laser at 2-week intervals. We found no significant differences in treatment efficacy (p = 0.14). The 1064-nm laser group referred significantly less pain than the 532-nm laser group (p = 0.0001). Side effects were detected in 5 patients in the 532-nm laser group. The difference of the side effects was statistically significant (p = 0.04). Two patients in 532-nm laser group were recurred and none in 1064-nm laser group. On a univariate logistic regression analysis, lesions with brown color, small size, and irregular edges were significantly associated with better outcomes (> 50% clearance). Multivariate logistic regression analysis found that brown lesions and lesions with irregular edges had higher odds of getting > 50% clearance (p < 0.05). In conclusion, the 1064-nm LFQS laser produced fewer side effects, less pain, and shorter recovery time than the 532-nm laser. Irregular-bordered, smaller, brown lesions improved better than smooth-bordered, larger, light brown lesions. Moreover, the 1064-nm laser may be a better choice for treating large size CALMs. However, no significant differences were found in terms of the treatment efficacy and recurrence.Keywords
Funding Information
- the most important clinical discipline in Shanghai (2017ZZ2026-02)
- National Nature Science Foundation of China (81630083)
This publication has 24 references indexed in Scilit:
- Preliminary experience of the Q‐switched 1064‐nm neodymium:yttrium aluminum garnet laser in the treatment of Café‐au‐lait maculesJournal of the European Academy of Dermatology and Venereology, 2018
- High‐fluence 1064‐nm Q‐Switched Nd: YAG laser: Safe and effective treatment of café‐au‐lait macules in Asian patientsJournal of Cosmetic Dermatology, 2018
- Picosecond 532-nm neodymium-doped yttrium aluminium garnet laser—a novel and promising modality for the treatment of café-au-lait maculesLasers in Medical Science, 2017
- Response to Laser Treatment of Café au Lait Macules Based on Morphologic FeaturesJAMA Dermatology, 2017
- Novel use of non‐ablative fractional photothermolysis for café‐au‐lait macules in darker skin typesLasers in Surgery and Medicine, 2016
- Fractional 532-nm Q-switched Nd:YAG laser: One of the safest novel treatment modality to treat café-au-lait maculesJournal of Cosmetic and Laser Therapy, 2016
- A low-fluence 1064-nm Q-switched neodymium-doped yttrium aluminium garnet laser for the treatment of café-au-lait maculesJournal of the American Academy of Dermatology, 2015
- Treatment of segmental café-au-lait macules using 1064-nm Q-switched Nd:YAG laser with low pulse energyClinical and Experimental Dermatology, 2009
- LASER TREATMENT OF BENIGN PIGMENTED LESIONS IN CHILDREN: EFFECTIVE LONG‐TERM BENEFITS OF THE Q‐SWITCHED FREQUENCY‐DOUBLED ND:YAG AND LONG‐PULSED ALEXANDRITE LASERSPediatric Dermatology, 2004
- Treatment of individual café au lait macules with the Q-switched Nd:YAG: A clinicopathologic correlationJournal of Cutaneous Laser Therapy, 1999