Secondary ion mass spectroscopy analysis for aluminum surfaces treated by glow discharge cleaning

Authors:

Abstract
Glow discharge cleaning treatments on aluminum surfaces were studied by the secondary ion mass spectroscopy method. The cleaning effects of direct current and radio frequency glow discharges with H2 and Ar gases were compared. The elements or compounds of the contamination or reaction depositions were identified from analyses of the mass spectra and energy distribution of the secondary ions. Base material, chemical solvents, sputtered depositions, hydrogen –oxygen–hydroxyls, and hydrocarbons were the five major sources of the secondary ions. The energy distribution curves were similar for secondary ions with similar compound complexity, and the cleaning effects were nearly identical for secondary ions with the same type of origin.