An online recursive ICA based real-time multichannel EEG system on chip design with automatic eye blink artifact rejection
Authors:
- 1 April 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 22, 1-4
Abstract
This paper presents an online recursive ICA (ORICA) based real-time multi-channel EEG system on chip design with automatic eye blink artifact rejection. Since EEG signals are very feeble, they are easy to be contaminated by artifacts. Among all artifacts, eye blink artifact dose the most significant harm to EEG signals. For acquiring artifact free EEG signals, ICA is a popular method for artifacts extraction. After extraction of ICA, eye blink artifacts are rejected to improve the reliability of EEG applications such as brain computer interfaces (BCIs). To promote the feasibility and convenience of BCIs, a real-time ICA algorithm, ORICA, is adopted in this system. With ORICA, the system immediately finishes each ICA result after each sample time. After each ICA result is generated, the automatic eye blink artifact rejection and inverse ICA are performed to acquire eye blink artifact free EEG signals in realtime. For system portability and high integration, a front-end interface of commercial IC, ADS1298 provided by TI, and Bluetooth interface, UART, are implemented. The system is designed used TSMC 90nm CMOS technology with 8 channels EEG processing in 128 Hz sample rate of raw data and consumes 8.56 mW at 50 MHz clock rate. The design methods of the proposed EEG system are provided in this paper. The performance and processing results of the system are also shown to reach 0.2532 s latency after each EEG sample time.Keywords
This publication has 8 references indexed in Scilit:
- Recursive independent component analysis for online blind source separation2012
- Energy-Efficient FastICA Implementation for Biomedical Signal SeparationIEEE Transactions on Neural Networks, 2011
- Automatic Artifact Rejection From Multichannel Scalp EEG by Wavelet ICAIEEE Sensors Journal, 2011
- A hardware-efficient VLSI implementation of a 4-channel ICA processor for biomedical signal measurement2011
- An ICA-based method for automatic eye blink artifact correction in multi-channel EEG2008
- Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signalsClinical Neurophysiology, 2004
- Independent Component Analysis Using an Extended Infomax Algorithm for Mixed Subgaussian and Supergaussian SourcesNeural Computation, 1999
- An Information-Maximization Approach to Blind Separation and Blind DeconvolutionNeural Computation, 1995