High-sensitive real-time PCR assays are routinely used to monitor HIV-1 infected subjects. Inter-assay discrepancies have been described at the low viral load (VL) end, where clinical decisions regarding possible virological rebound are based. A retrospective study was performed to analyze frequencies of viral blips after transition to the COBAS Ampliprep/COBAS TaqMan v2.0 HIV-1 assay (Taqman v2.0) in patients with prior undetectable VLs as measured with the Roche Cobas Ampliprep Amplicor HIV-1 Monitor Test, v1.5 (Amplicor) and was evaluated in comparison to a group of patients monitored with the Abbott Real-time HIV-1 assay (Abbott RT) during the same period of time. 85 of 373 patients with VLs below the limit of quantification with Amplicor had VLs >50 copies/mL after transition to the TaqMan v2.0 assay. Among these 74.1% had VLs ranging from 50–499 copies/mL, 22.9% had VLs >500 copies/mL. From 22 patients with initial Taqman v2.0 based VLs exceeding 500 copies/mL, 6 patients had VLs <20 copies/mL after novel VL measurement on a next visit. In our control group with VL quantification using the Abbott RT assay, only 1 patient became detectable and showed a VL of <40 copies/mL after new measurement. Transition to the Taqman v2.0 assay was accompanied by an increase of quantifiable HIV-1 VLs in patients with long term viral suppression under antiretroviral therapy that might be attributed to technical shortcomings of the Taqman v2.0 assay. A high test variability at the low VL end but also beyond was observed, making meaningful clinical interpretation of viral blips derived from different assays difficult.Keywords
This publication has 25 references indexed in Scilit:
- HIV-1 low-level viraemia assessed with 3 commercial real-time PCR assays show high variabilityBMC Infectious Diseases, 2012
- Comparison of the rate and size of HIV-1 viral load blips with Roche COBAS TaqMan HIV-1 versions 1.0 and 2.0 and implications for patient managementJournal of Clinical Virology, 2012
- Overestimation of Human Immunodeficiency Virus Type 1 Load Caused by the Presence of Cells in Plasma from Plasma Preparation TubesJournal of Clinical Microbiology, 2009
- Detection of HIV Type 1 Load by the Roche Cobas TaqMan Assay in Patients with Viral Loads Previously Undetectable by the Roche Cobas Amplicor MonitorClinical Infectious Diseases, 2009
- Evaluation of the Roche Cobas TaqMan and Abbott RealTime Extraction-Quantification Systems for HIV-1 SubtypesJAIDS Journal of Acquired Immune Deficiency Syndromes, 2007
- Comparison of the LCx Human Immunodeficiency Virus (HIV) RNA Quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan Assays for Quantitation of HIV Type 1 RNA in PlasmaJournal of Clinical Microbiology, 2006
- Update on HIV-1 viral load blips.2006
- Increased levels of HIV RNA detected in samples with viral loads close to the detection limit collected in Plasma Preparation Tubes™ (PPT)Journal of Clinical Virology, 2006
- Transient Viremia in HIV-Infected Patients and Use of Plasma Preparation TubesClinical Infectious Diseases, 2005
- Toward HIV Eradication or Remission: The Tasks AheadScience, 1998