Targeted Formation of Biofilms on the Surface of Graphite Electrodes as an Effective Approach to the Development of Biosensors for Early Warning Systems
Authors:
- Anna KharkovaAnna Kharkova
- Roman PerchikovRoman Perchikov
- Saniyat KurbanalievaSKSaniyat Kurbanalieva
- Kristina OsinaKOKristina Osina
- Nadezhda PopovaNadezhda Popova
- Andrey MachulinAMAndrey Machulin
- Olga KamaninaOKOlga Kamanina
- Evgeniya SaverinaESEvgeniya Saverina
- Ivan SaltanovISIvan Saltanov
- Sergey MelenkovSMSergey Melenkov
- Denis ButusovDenis Butusov
- Vyacheslav ArlyapovVyacheslav Arlyapov
Open Access
- 9 May 2024
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 14 (5) , 239
Abstract
Biofilms based on bacteria Pseudomonas veronii (Ps. veronii) and Escherichia coli (E. coli) and yeast Saccharomyces cerevisiae (S. cerevisiae) were used for novel biosensor creation for rapid biochemical oxygen demand (BOD) monitoring. Based on the electrochemical measurement results, it was shown that the endogenous mediator in the matrix of E. coli and Ps. veronii biofilms and ferrocene form a two-mediator system that improves electron transport in the system. Biofilms based on Ps. veronii and E. coli had a high biotechnological potential for BOD assessment; bioreceptors based on such biofilms had high sensitivity (the lower limits of detectable BOD5 concentrations were 0.61 (Ps. veronii) and 0.87 (E. coli) mg/dm3) and high efficiency of analysis (a measurement time 5–10 min). The maximum biosensor response based on bacterial biofilms has been observed in the pH range of 6.6–7.2. The greatest protective effect was found for biofilms based on E. coli, which has high long-term stability (151 days for Ps. veronii and 163 days for E. coli). The results of the BOD5 analysis of water samples obtained using the developed biosensors had a high correlation with the results of the standard 5-day method (R2 = 0.9820, number of tested samples is 10 for Ps. veronii, and R2 = 0.9862, number of tested samples is 10 for E. coli). Thus, biosensors based on Ps. veronii biofilms and E. coli biofilms could be a novel analytical system to give early warnings of pollution.Keywords
Funding Information
- Ministry of Science and Higher Education of the Russian Federation (FEWG-2024-0004)
This publication has 44 references indexed in Scilit:
- Heavy metal–induced stress in eukaryotic algae—mechanisms of heavy metal toxicity and tolerance with particular emphasis on oxidative stress in exposed cells and the role of antioxidant responseEnvironmental Science and Pollution Research, 2022
- A kinetic approach to the formation of two-mediator systems for developing microbial biosensors as exemplified by a rapid biochemical oxygen demand assay3 Biotech, 2021
- Bacterial Cellulose Immobilized S. cerevisiae as Microbial Sensor for Rapid BOD DetectionFibers and Polymers, 2021
- Phenazine oxidation by a distal electrode modulates biofilm morphogenesisBiofilm, 2020
- Dual detection of biochemical oxygen demand and nitrate in water based on bidirectional Shewanella loihica electron transferBioresource Technology, 2020
- Registration of BOD using Paracoccus yeei bacteria isolated from activated sludge3 Biotech, 2020
- Extracellular secretion of feruloyl esterase derived from Lactobacillus crispatus in Escherichia coli and its application for ferulic acid productionBioresource Technology, 2019
- Glucose biosensor based on screen-printed electrode modified with silicone sol–gel conducting matrix containing carbon nanotubes3 Biotech, 2019
- Kinetics of Pseudomonas veronii 2E biofilm development under different nutritional conditions for a proper bioreactor designBiochemical Engineering Journal, 2016
- A microplate spectrofluorometric assay for bacterial biofilmsJournal of Industrial Microbiology and Biotechnology, 2006