Viral Target Capture Sequencing of Air Samples v1

Authors:

Abstract
Viral target capture methods used on air samples collected within congregate settings have been shown to be an effective tool to generate sequencing reads and detect viral species (1-3). The David and Shelby O'Connor labs at the University of Wisconsin-Madison regularly collect and prepare air samples with Illumina's viral target capture panel called the Viral Surveillance Panel v2 (VSP2). The following protocol describes our lab's entire viral target capture workflow. It includes the process of elution, nucleic acid isolation, pooling, cleaning and concentrating, library preparation with target capture, and normalization before sequencing. We typically sequence the prepared samples on a NovaSeq 10 billion read 2x150 flow cell, requesting a full lane, or the equivalent of 1.25 billion reads.