Comparison of DLIR-H and ASIR algorithms for image reconstruction in low-dose chest CT of pediatric mycoplasma pneumoniae pneumonia: a cross-sectional study
Open Access
- 1 April 2026
- journal article
- Published by AME Publishing Company in Translational Pediatrics
- Vol. 15 (4) , 101
Abstract
Background: Pediatric Mycoplasma pneumoniae pneumonia (MPP) accounts for a significant number of cases of community-acquired pneumonia, and chest computed tomography (CT) is critical for its early diagnosis and prognosis assessment. However, clinical utilization is restricted due to concerns regarding radiation exposure. Adaptive statistical iterative reconstruction (ASIR) has been extensively employed in low-dose pediatric CT but suffers from noise texture distortion. In contrast, deep learning image reconstruction (DLIR) has shown promise for enhancing image quality in adult CT. Nevertheless, the comparative effectiveness of DLIR and ASIR in low-dose chest CT for pediatric MPP remains unvalidated, presenting a significant knowledge gap that this study endeavours to bridge. Methods: In this retrospective cross-sectional study, consecutive pediatric patients who underwent low-dose chest CT (September 2023–March 2024) who were positive for MP-IgM and negative for other respiratory pathogen antibodies were included; patients with incomplete data, poor scan cooperation or a body mass index (BMI) ≥25 kg/m2 were excluded. The raw CT data were reconstructed via ASIR at 0%, 50%, and 80% blending factors and DLIR at low, medium, and high-strength (DLIR-H) levels, using a standard kernel and a 1.25 mm slice thickness/interval. The standard deviation value of subcutaneous fat, the signal-to-noise ratio (SNR) of the lung parenchyma, and the contrast-to-noise ratio (CNR) of MPP were used to objectively evaluate the image quality. The subjective evaluation was scored by two senior radiologists using a 5-point scoring method, and the intraclass correlation coefficient (ICC) was determined for consistency analysis. Results: Among the 235 screened patients, 142 (77 males and 65 females) were included (8.427±3.706 years), with a mean BMI of 16.19±1.83 kg/m2. The mean effective dose was 1.17 (0.84–2.53 mSv), which met the Chinese low-dose guidelines. DLIR-H exhibited the lowest background noise (21.69, 38.3% lower than that of ASIR-80%) and the highest CNR of MPP (28.22, 14.7% higher than that of ASIR-80%). ASIR-80% had the highest SNR of the lung parenchyma (−14.46). DLIR-H achieved the highest subjective score (4.83±0.400, all P0.7). Conclusions: DLIR-H outperforms ASIR variants in low-dose pediatric chest CT, with minimal background noise, the highest lesion CNR and the best subjective quality at a clinically low effective dose, enhancing radiologists’ diagnostic confidence and balancing radiation safety with imaging quality. Limitations include the retrospective design, DLIR-H’s inferior lung parenchyma SNR, GE-only equipment compatibility, and unassessed MPP diagnostic accuracy. Prospective multicentre validation is required for broader clinical translation.Keywords
This publication has 25 references indexed in Scilit:
- Impact of Deep Learning-based Optimization Algorithm on Image Quality of Low-dose Coronary CT Angiography with Noise Reduction: A Prospective StudyAcademic Radiology, 2020
- Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial ExperienceAmerican Journal of Roentgenology, 2020
- Comparison of conventional chest x ray with a novel projection technique for ultra‐low dose CTMedical Physics, 2020
- Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom studyEuropean Radiology, 2020
- Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CTBritish Journal of Radiology, 2019
- Deep learning–based image restoration algorithm for coronary CT angiographyEuropean Radiology, 2019
- Detection of Colorectal Hepatic Metastases Is Superior at Standard Radiation Dose CT versus Reduced Dose CTRadiology, 2019
- Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed TomographyJACC: Cardiovascular Imaging, 2018
- Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose LevelsRadiology, 2015
- CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dosePediatric Radiology, 2015