An improved starting strategy for voltage-source inverter fed three phase induction motor drives under inverter fault conditions
Authors:
- A.K. MajumdarAMA.K. Majumdar
- 1 July 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 15 (4) , 726-732
Abstract
Three phase voltage-fed inverter induction motor drives are prone to shoot through and other inverter faults that cause the drive system to shut down. The paper describes a novel strategy for restarting the drive in variable voltage variable frequency single phase mode in the presence of open base drive and shoot through fault in the inverter. The proposed method requires only the motor terminal voltages and currents to be measured. Therefore, it can be applied to even low performance open loop drives with the addition of two motor terminal voltage sensors. The starting algorithm has been verified by computer simulation and experiments on a 1 hp laboratory prototype. Experimental results are in good agreement with simulation predictions. The starting strategy described in this paper is expected to provide an economic alternative to more expensive redundancy techniques which find justification only in a few specialized applications.Keywords
This publication has 5 references indexed in Scilit:
- On-line search based pulsating torque compensation of a fault mode single phase variable frequency induction motor drive2002
- A strategy for improving reliability of field oriented controlled induction motor drives2002
- Fault mode single-phase operation of a variable frequency induction motor drive and improvement of pulsating torque characteristicsIEEE Transactions on Industrial Electronics, 1994
- Investigation of fault modes of voltage-fed inverter system for induction motor driveIEEE Transactions on Industry Applications, 1994
- Remedial strategies for brushless DC drive failuresIEEE Transactions on Industry Applications, 1990