Use of a systematic review to inform the infection risk for biomedical engineers and technicians servicing biomedical devices
- 21 October 2011
- journal article
- review article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 34 (4) , 431-440
Abstract
Many microorganisms responsible for hospital-acquired infections are able to stay viable on surfaces with no visible sign of contamination, in dry conditions and on non-porous surfaces. The infection risk to biomedical staff when servicing biomedical devices is not documented. An indirect approach has been used to examine the different aspects that will affect the risk of infection including a systematic review of microbial contamination and transmission relating to biomedical devices. A systematic review found 58% of biomedical devices have microbial contamination with 13% having at least one pathogenic organism. These microbes can persist for some months. Occupational-infections of biomedical service staff are low compared to other healthcare workers. A biomedical device with contaminated surface or dust was identified as the source of patient outbreaks in 13 papers. The cleaning agent most tested for removal of micro-organisms from devices was alcohol swabs, but sterile water swabs were also effective. However, manufacturers mainly recommend (74%) cleaning devices with water and detergent. Biomedical engineers and technicians have a small risk of being exposed to dangerous micro-organisms on most biomedical devices, but without skin breakage, this exposure is unlikely to cause ill-health. It is recommended that biomedical staff follow good infection control practices, wipe devices with detergent, sterile water or alcohol swabs as recommended by the manufacturer before working on them, and keep alcohol hand rubs accessible at all benches.Keywords
This publication has 50 references indexed in Scilit:
- Surveillance of Healthcare-Acquired Infections in Queensland, Australia: Data and Lessons From the First 5 YearsInfection Control & Hospital Epidemiology, 2008
- Methicillin‐resistant Staphylococcus aureus (MRSA): “missing the wood for the trees”Medical Journal of Australia, 2008
- Widespread Environmental Contamination Associated With Patients With Diarrhea and Methicillin-ResistantStaphylococcusaureus Colonization of the Gastrointestinal TractInfection Control & Hospital Epidemiology, 2007
- Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unitJournal of Hospital Infection, 2005
- Use of a Heminested Reverse Transcriptase PCR Assay for Detection of Astrovirus in Environmental Swabs from an Outbreak of Gastroenteritis in a Pediatric Primary Immunodeficiency UnitJournal of Clinical Microbiology, 2005
- Computers in anesthesia and intensive care: Lack of evidence that the central unit serves as reservoir of pathogensInternational Journal of Hygiene and Environmental Health, 2005
- Transmission of Vancomycin-Resistant Enterococcus in a Neonatal Intensive Care UnitThe Pediatric Infectious Disease Journal, 2005
- Use of pulsed-field gel electrophoresis toinvestigate an outbreak of Serratia marcescens infection in a neonatal intensive care unitJournal of Hospital Infection, 2001
- ABC of Work Related Disorders: OCCUPATIONAL INFECTIONSBMJ, 1996
- An Outbreak of Mupirocin-Resistant Staphylococcus aureus on a Dermatology Ward Associated with an Environmental ReservoirInfection Control & Hospital Epidemiology, 1993