A High Data Rate Implantable MIMO Antenna for Deep Implanted Biomedical Devices
- 15 September 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 70 (2) , 998-1007
Abstract
In this article, a compact multiple-input multiple-output (MIMO) implantable antenna based on meandered resonators is proposed for use in medical implantable devices. Such devices require compactness and high data rates. Regarding compactness, the antenna has a size of $5.35\times 6.2 \times 0.12$ mm3 (operating frequency of 2.45 GHz) which is one of the smallest sizes reported in the literature for this class of antennas. This compactness is achieved using the meandered resonators and slots in the ground plane. For high data rates, the proposed antenna is of MIMO configuration and consists of two probe-fed elements that share the same ground plane and are placed at a distance (edge-to-edge) of 0.4 mm from each other. This configuration reduces multipath distortion and achieves seamless communications with high data rates as evident from conducted link budget analysis and MIMO channel studies. The ex vivo measurements (S-parameters, gain, and radiation patterns) are performed on the proposed antenna when placed inside a capsule and implanted in minced meat. A bandwidth of 320 MHz and isolation of 28 dB are achieved at the design frequency along with omni-directional radiation patterns with a peak realized gain of −20.5 dBi. Specific absorption rate (SAR) analysis and input power studies are performed to ensure patient’s safety. The result shows that the antenna has a safe 10 g SAR of 402.8 W/kg at an input power of 1 W. Also, the capsule device can be operated at a safe power level of 3.97 mW, which is far greater than the maximum allowable power limit ( $25~\mu \text{W}$ ).
Keywords
Funding Information
- Kuwait University Research (N. [EE01/20])
This publication has 48 references indexed in Scilit:
- MIMO antennas for capsule endoscope systems2016
- Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring SystemIEEE Journal of Biomedical and Health Informatics, 2016
- A Miniaturized CSRR Loaded Wide-Beamwidth Circularly Polarized Implantable Antenna for Subcutaneous Real-Time Glucose MonitoringIEEE Antennas and Wireless Propagation Letters, 2016
- A Dual-Band HF and UHF Antenna System for Implanted Neural Recording and Stimulation DevicesIEEE Antennas and Wireless Propagation Letters, 2016
- A Novel Differentially Fed Compact Dual-Band Implantable Antenna for Biotelemetry ApplicationsIEEE Antennas and Wireless Propagation Letters, 2016
- Small-Size Dual-Antenna Implantable System for Biotelemetry DevicesIEEE Antennas and Wireless Propagation Letters, 2016
- Flexible, Polarization-Diverse UWB Antennas for Implantable Neural Recording SystemsIEEE Transactions on Biomedical Circuits and Systems, 2015
- A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure MonitorIEEE Transactions on Biomedical Circuits and Systems, 2010
- From theory to practice: an overview of MIMO space-time coded wireless systemsIEEE Journal on Selected Areas in Communications, 2003
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996