Seeing Red: PPG Biometrics Using Smartphone Cameras
Authors:
Preprint
Abstract
In this paper, we propose a system that enables photoplethysmogram (PPG)-based authentication by using a smartphone camera. PPG signals are obtained by recording a video from the camera as users are resting their finger on top of the camera lens. The signals can be extracted based on subtle changes in the video that are due to changes in the light reflection properties of the skin as the blood flows through the finger. We collect a dataset of PPG measurements from a set of 15 users over the course of 6-11 sessions per user using an iPhone X for the measurements. We design an authentication pipeline that leverages the uniqueness of each individual's cardiovascular system, identifying a set of distinctive features from each heartbeat. We conduct a set of experiments to evaluate the recognition performance of the PPG biometric trait, including cross-session scenarios which have been disregarded in previous work. We found that when aggregating sufficient samples for the decision we achieve an EER as low as 8%, but that the performance greatly decreases in the cross-session scenario, with an average EER of 20%.Keywords
All Related Versions
- Version 1, 2020-04-15, ArXiv
- Published version: , 3565.
This publication has 12 references indexed in Scilit:
- A review on wearable photoplethysmography sensors and their potential future applications in health careInternational Journal of Biosensors & Bioelectronics, 2018
- Mutual Information between Discrete and Continuous Data SetsPLOS ONE, 2014
- A preliminary study on continuous authentication methods for photoplethysmographic biometrics2013
- Multiparameter Respiratory Rate Estimation From the PhotoplethysmogramIEEE Transactions on Biomedical Engineering, 2013
- DEAP: A Database for Emotion Analysis ;Using Physiological SignalsIEEE Transactions on Affective Computing, 2011
- Feature selection based on mutual information criteria of max-dependency, max-relevance, and min-redundancyIEEE Transactions on Pattern Analysis and Machine Intelligence, 2005
- Digital pulse contour analysis: investigating age-dependent indices of arterial compliancePhysiological Measurement, 2005
- Physiological Signal Based Entity Authentication for Body Area Sensor Networks and Mobile Healthcare Systems2005
- Left ventricular end-systolic pressure estimated from measurements in a peripheral arteryJournal of Cardiothoracic and Vascular Anesthesia, 1991
- Dynamic programming algorithm optimization for spoken word recognitionIEEE Transactions on Acoustics, Speech, and Signal Processing, 1978