Abstract
Weak magnetic flux leak detection is one of the most important non-destructive testing and measurement methods for pipelines. Since different defects cause different damage, it is necessary to classify the different types of defects. Traditional machine learning methods of defect type identification mainly use feature analysis methods and rely on expert a priori knowledge and the ability of designers. These methods have the following weaknesses: a priori knowledge needs to be designed iteratively, and a priori knowledge design relies on expert experience. In recent years, the rapid development of deep learning methods in the field of machine vision has led to the development of defect analysis in the industry. However, most deep learning methods lack the ability to analyze both detailed information and the overall structure. In this paper, we propose graph convolution networks for splitting and fusing multiple graphs of detail graphs and a root graph. Detail information (detail graphs) provides detailed information for the detection of WMFLs. The structure information (root graph) provides structural information for the detection of WMFLs. This paper uses simulation data and experimental data to verify that the proposed method can identify stress defects and corrosion defects well. The paper explains the experimental results in detail to demonstrate the superiority of the method in industrial methods.Keywords
Funding Information
- National Natural Science Foundation of China (U22A2055, 62173081, XLYC2002032)
- Liaoning Revitalization Talents Program (U22A2055, 62173081, XLYC2002032)
This publication has 33 references indexed in Scilit:
- Research on internal and external defect identification of drill pipe based on weak magnetic inspectionInsight - Non-Destructive Testing and Condition Monitoring, 2014
- Three-axis magnetic flux leakage in-line inspection simulation based on finite-element analysisChinese Physics B, 2013
- Experimental Research on Metal Magnetic Memory MethodExperimental Mechanics, 2011
- Quantitative study of metal magnetic memory signal versus local stress concentrationNDT & E International, 2010
- Empirical structure for characterizing metal loss defects from radial magnetic flux leakage signalNDT & E International, 2010
- Large Deformation Finite-Element Analysis of Submarine Landslide Interaction with Embedded PipelinesInternational Journal of Geomechanics, 2010
- FEM modelling techniques of magnetic flux leakage-type NDT for ferromagnetic plate inspectionsJournal of Magnetism and Magnetic Materials, 2006
- Application of the Villari effect to electric power harvestingJournal of Applied Physics, 2006
- 3D FEM analysis in magnetic flux leakage methodNDT & E International, 2006
- Magnetoelastic Villari effect in Mn–Zn ferritesJournal of Magnetism and Magnetic Materials, 2000