An Economic Analysis of Direct Costs of Distal Radius Fixation and the Implications of a Disposable Distal Radius Kit
- 27 January 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 35 (9) , e346-e351
Abstract
Objective: To assess the direct costs of distal radius fracture volar plate (VP) fixation and to create a model to examine the effect of these cost drivers. Materials and Methods: Retrospectively, 744 distal radius fractures treated with open reduction and internal fixation (ORIF) were identified. The outcomes assessed included (1) the direct costs related to distal radius ORIF and (2) if a VP alone was amenable. Costs were represented as a cost ratio relative to the average cost of distal radius ORIF, where the average value is set as 1.0. Simulation models were run with all cost drivers (sex, age, open fracture, intra-articular fracture, and ancillary fixation) and with only ancillary fixation as a cost driver. Results: The cost ratio ranged from 0.61 to 1.81 and ancillary fixation was associated with increased implant costs in multivariable analysis. In the simulations, the cost ratio ranged from 0.96 to 1.23 when all cost drivers were included and from 0.99 to 1.20 if only ancillary fixation was included as a cost driver, a reduction of the range by 22.2%. Older patients, females, closed fractures, and extra-articular fractures were more amenable to VP fixation alone. Conclusions: Eighty-three percent of the surgically treated distal radius fractures were treated with VP fixation alone. A disposable kit could help limit cost variance per case by roughly 22%, as only ancillary fixation varies these costs. Closed fractures and extra-articular fractures in older patients or female patients are more amenable to VP fixation alone. Level of Evidence: Economic Level III. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 24 references indexed in Scilit:
- Eco-efficiency of disposable and reusable surgical instruments—a scissors caseThe International Journal of Life Cycle Assessment, 2013
- Performance and Cost of Disposable Biopsy Forceps in Upper Gastrointestinal Endoscopy: Comparison with Reusable Biopsy ForcepsClinical Endoscopy, 2012
- Current and Future National Costs to Medicare for the Treatment of Distal Radius Fracture in the ElderlyThe Journal of Hand Surgery, 2011
- American Academy of Orthopaedic Surgeons Clinical Practice Guideline onJournal of Bone and Joint Surgery, 2011
- Trends in the United States in the Treatment of Distal Radial Fractures in the ElderlyJournal of Bone and Joint Surgery, 2009
- A Modification of the Elixhauser Comorbidity Measures Into a Point System for Hospital Death Using Administrative DataMedical Care, 2009
- Fractures of the Distal Part of the RadiusJournal of Bone and Joint Surgery, 2008
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- Sterilization Wrap Inspections Do Not Adequately Evaluate Instrument SterilityClinical Orthopaedics and Related Research, 2007
- Comparison of economic and environmental impacts between disposable and reusable instruments used for laparoscopic cholecystectomySurgical Endoscopy, 2004