A Novel Algorithm for Locating Faults on Transposed/Untransposed Transmission Lines Without Utilizing Line Parameters
Authors:
- 23 August 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 25 (4) , 2328-2338
Abstract
This paper puts forward a novel algorithm for locating faults on power transmission lines without requiring line parameters. The algorithm utilizes unsynchronized measurements of voltages and currents from both ends of a transmission line and is formulated in terms of the fundamental frequency phasors of the measured signals. Both prefault and postfault phasors are processed for determining the sought distance to fault and the synchronization angle. The calculations are performed initially for a lumped parameter line model with neglecting shunt capacitance. Then, these results are used as starting values for an iterative process, where the impacts of the shunt capacitance of the line are considered. The proposed two-stage fault-location algorithm is applicable for transposed and untransposed transmission lines and is independent of the fault resistance and source impedances. Evaluation studies using reliable Alternate Transients Program-Electromagentic Transients Program simulation data verify that the proposed algorithm can yield quite accurate results.Keywords
This publication has 17 references indexed in Scilit:
- Fault-Location Algorithms Without Utilizing Line Parameters Based on the Distributed Parameter Line ModelIEEE Transactions on Power Delivery, 2009
- Unsynchronized Fault Location Based on Distributed Parameter Line ModelElectric Power Components and Systems, 2007
- Accurate Location of Faults on Power Transmission Lines With Use of Two-End Unsynchronized MeasurementsIEEE Transactions on Power Delivery, 2006
- Unsynchronised two-terminal transmission-line fault-location without using line parametersIEE Proceedings - Generation, Transmission and Distribution, 2006
- Fault Location on a Transmission Line Using Synchronized Voltage MeasurementsIEEE Transactions on Power Delivery, 2004
- A new adaptive PMU based protection scheme for transposed/untransposed parallel transmission linesIEEE Transactions on Power Delivery, 2002
- An adaptive PMU based fault detection/location technique for transmission lines. I. Theory and algorithmsIEEE Transactions on Power Delivery, 2000
- Automated transmission line fault analysis using synchronized sampling at two endsIEEE Transactions on Power Systems, 1996
- Development of an advanced transmission line fault location system. II. Algorithm development and simulationIEEE Transactions on Power Delivery, 1992
- Development of a New Type Fault Locator Using the One-Terminal Voltage and Current DataIEEE Transactions on Power Apparatus and Systems, 1982