Automated measurement of proprioception following stroke
Authors:
- 1 January 2008
- journal article
- research article
- Published by Taylor & Francis in Disability and Rehabilitation
- Vol. 30 (24) , 1829-1836
Abstract
Background. Proprioception provides feedback which is essential for adequate motor control. Despite having detrimental functional implications, the assessment of proprioception deficits in current clinical practice is mostly qualitative and inadequate for diagnosis and longitudinal monitoring of subtle impairments and their effect on motor function. Purpose. To evaluate a novel quantitative approach to the assessment of proprioception deficits in stroke patients. Method. We designed and implemented an automated protocol where a magnetic motion tracking system and a sensor attached to each of the patient's hands, enables registration of trajectories in 3D coordinates. In this protocol the patient's affected and healthy hands are placed respectively below and above a square board. With vision blocked, the subject's affected hand is passively moved to one of four locations, and then the patient is instructed to actively position the healthy hand directly above his/her perceived location of the affected hand. The positional difference between the two hands is automatically recorded by the system. This procedure is repeated several times and the magnitude and direction of errors are used to quantify the proprioception deficit. The data for this pilot study was collected in a sample of 22 stroke patients and an age-matched group of neurologically intact subjects. Results. Stroke patients had significantly higher mean distance error compared with the control group (average values of 7.9 and 5.3 cm, respectively), and showed higher instability (variance) in repeated performance (average values of the standard deviation of errors 3.4 and 1.8 cm, respectively). Significant correlation was found between the mean distance error and the results of semi-quantitative clinical tests of proprioception. Conclusion. The system provides a reliable quantitative measure of upper limb proprioception, offering considerable advantage over the traditional means applied in the clinic.Keywords
This publication has 13 references indexed in Scilit:
- Pelvic Floor Muscle Biofeedback in the Treatment of Urinary Incontinence: A Literature ReviewApplied Psychophysiology and Biofeedback, 2006
- Calibrated Forceps: A Useful Tool to Study Mechanical NociceptionThe Journal of Pain, 2006
- Efficacy of Biofeedback-Based Treatments for Temporomandibular DisordersApplied Psychophysiology and Biofeedback, 2005
- Assessment of spatial attention after brain damage with a dynamic reaction time testJournal of the International Neuropsychological Society, 2005
- A novel device for the measurement of proprioception in the handRheumatology, 2005
- The Two-Point Discrimination Test – Time For a Re-Appraisal?Journal of Hand Surgery (European Volume), 2004
- Rehabilitation of somatic sensation and related deficit of motor control in patients with pure sensory stroke11No commercial party having a direct financial interest in the results of the research supporting this article has or will confer a benefit upon the author(s) or upon any organization with which the author(s) is/are associated.Archives of Physical Medicine and Rehabilitation, 2003
- von Frey hairs: new materials for a new designEuropean journal of pain, 2001
- A controlled trial of the retraining of the sensory function of the hand in stroke patients.Journal of Neurology, Neurosurgery & Psychiatry, 1993
- The repeatability of testing with Semmes-Weinstein monofilamentsThe Journal of Hand Surgery, 1987