Analysis and Mitigation of Pose Estimation Uncertainty on SE(3) for Magnetic Localization
- 8 May 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 42 (15523098) , 2178-2195
Abstract
Magnetic localization, owing to its immunity to line-of-sight occlusion and non-contact nature, is considered a promising technology for medical applications. While it is intuitive that localization performance degrades as the target moves farther from the sensor array, uncertainty analysis has long been overlooked, which is essential for quantifying localization quality. In this work, we present a pose estimation and uncertainty analysis framework on SE(3) for magnetic source localization using sensor arrays, which enables concise formulation of the problem and quantitative assessment of the results. The volume of the uncertainty ellipsoid is used to characterize localization confidence, while the surface shape in Cartesian space is used for visualization. This also provides insight into the effective workspace of the magnetic localization system prior to deployment. Guided by this analysis, we designed a movable magnetic sensor array to expand the limited sensing volume and mitigate localization uncertainty, thereby enhancing overall localization performance. Simulations and pose tracking experiments validate the effectiveness of this framework. By dynamically moving the sensor array to minimize the volume of the uncertainty ellipsoid, localization errors are reduced compared with static and projection-based strategies by 67.04%, 16.51% in position and 43.87%, 20.73% in orientation, respectively. Furthermore, phantom experiments on distal locking screw alignment and magnetic capsule endoscope tracking demonstrate the system's capability in improving localization accuracy (reducing alignment errors by 71.88%) and expanding the effective workspace by several folds.Keywords
Funding Information
- National Key R&D Program of China (2025YFF0521600)
- National Natural Science Foundation of China (T2293720/T2293724)
- National Natural Science Foundation of China (62303407)
- Key R&D Program of Zhejiang (2026SDXT001(SD2))
- State Key Laboratory of Electrical Insulation and Power Equipment (EIPE24212)
- Xiaomi Foundation
This publication has 40 references indexed in Scilit:
- A movable long-term implantable soft microfibre for dynamic bioelectronicsNature, 2025
- Magnetically driven biohybrid blood hydrogel fibres for personalized intracranial tumour therapy under fluoroscopic trackingNature Biomedical Engineering, 2025
- Active exploration and reconstruction of vascular networks using microrobot swarmsNature Machine Intelligence, 2025
- State Estimation for Robotics2024
- Localization strategies for robotic endoscopic capsules: a reviewExpert Review of Medical Devices, 2019
- Magnetic dipole model in the near-field2015
- Lie Groups and Lie Algebras in Robotics2006
- Design and control of a microrobotic system using magnetic levitationIEEE/ASME Transactions on Mechatronics, 2002
- Biomechanical analysis of the mechanism of interlocking nail failureArchives of orthopaedic and trauma surgery, 1992
- Unmasking Multivariate Outliers and Leverage PointsJournal of the American Statistical Association, 1990