Topology/Floorplan/Pipeline Co-Design of Cascaded Crossbar Bus
Authors:
- 27 May 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 17 (8) , 1034-1047
Abstract
On-chip bus design has a significant impact on the die area, power consumption, performance and design cycle of complex system-on-chips (SoCs). Especially, for high frequency systems having on-chip buses pipelined extensively to cope with long wire delay, a naive bus design may yield a significant area/power cost mostly due to bus pipeline cost. The topology, floorplan, and pipeline are the most important design factors that affect the cost and frequency of the on-chip bus. Since they are strongly correlated with each other, it is imperative to codesign all of the three. In this paper, we present an automated codesign method for cascaded crossbar bus design. We present CADBUS (CAscadeD crossbar BUS design tool), an automated tool for AXI-based cascaded crossbar bus architecture design. The primary objective of this study is to design a cascaded crossbar bus, including the topology/floorplan/bus pipelines, having minimum area/power cost while satisfying the given constraints of communication bandwidth/latency or frequency. Experimental results of the three industrial strength SoCs show that, compared to the existing approach, the proposed method gives as much as 11.6%-34.2% (9.9%-33.5%) savings in bus area (power consumption).Keywords
This publication has 13 references indexed in Scilit:
- Communication Architecture Synthesis of Cascaded Bus Matrix2007
- Communication architecture optimization: making the shortest path shorter in regular networks-on-chip2006
- Æthereal Network on Chip:Concepts, Architectures, and ImplementationsIEEE Design & Test of Computers, 2005
- An Application-Specific Design Methodology for STbus Crossbar Generation2005
- FLEXBUS2005
- Guaranteed bandwidth using looped containers in temporally disjoint networks within the nostrum network on chip2004
- Rectangle-packing-based module placement2002
- Latency-guided on-chip bus network design2002
- Architectural power optimization by bus splitting2000
- Buffer insertion for noise and delay optimizationIEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, 1999