Upper-Extremity Venography: CO2versus Iodinated Contrast Material
Authors:
- Sam HeyeSHSam Heye
- Geert MaleuxGMGeert Maleux
- Guy J. MarchalGMGuy J. Marchal
- 1 October 2006
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (1) , 291-297
Abstract
To determine prospectively the diagnostic performance of CO(2) venography, by using conventional venography with iodinated contrast material as the reference standard, for the preoperative evaluation of upper-limb and central veins before creation of fistulas for hemodialysis access. The study was approved by the institutional review board, and informed consent was obtained from all patients. Twenty-two patients underwent comparative CO(2) and conventional venography of upper-extremity and central veins. Two independent observers evaluated the opacification of the veins and grade of stenosis, if present. Interobserver agreements were estimated with the Cohen kappa coefficient. Calculations of sensitivity, specificity, and accuracy were used for intertechnique observations. For CO(2) venography, global interobserver agreement was good, with a kappa value of 0.90 (range, 0.71-1.00; 95% confidence interval: 0.84, 0.95). A kappa value of 0.96 (range, 0.86-1.00; 95% confidence interval: 0.93, 0.99) was calculated for global interobserver agreement for conventional venography. The sensitivity, specificity, and accuracy of CO(2) venography for all vein segments were 97%, 85%, and 95%, respectively. CO(2) venography had a sensitivity of 97% and a specificity of 85% in the assessment of upper-limb and central vein patency and stenosis, with conventional venography used as the reference standard.Keywords
This publication has 12 references indexed in Scilit:
- US Vascular Mapping before Hemodialysis Access PlacementRadiology, 2000
- Assessment of CO2 Arteriography in Arterial Occlusive Disease of the Lower ExtremitiesJournal of Vascular and Interventional Radiology, 2000
- Hemodialysis Fistula: Preoperative MR Venography—A Promising but Partial ViewRadiology, 2000
- Digital Subtraction Angiography of the Abdominal Aorta and Lower Extremities: Carbon Dioxide versus Iodinated Contrast MaterialJournal of Vascular and Interventional Radiology, 1999
- Hemodialysis access fistula creation: preoperative assessment with MR venography and comparison with conventional venography.Radiology, 1998
- Densitometric analysis of eccentric vascular stenoses: Comparison of CO2 and iodinated contrast mediaAcademic Radiology, 1996
- Carbon dioxide digital subtraction angiography: expanding applications and technical evolution.American Journal of Roentgenology, 1995
- Carbon dioxide gas as a venous contrast agent to guide upper-arm insertion of central venous cathetersCardioVascular and Interventional Radiology, 1995
- Venography with carbon dioxide as a contrast agentCardioVascular and Interventional Radiology, 1995
- Comparison of Diagnostic Accuracy with Carbon Dioxide versus Iodinated Contrast Material in the Imaging of Hemodialysis Access FistulasJournal of Vascular and Interventional Radiology, 1994